Operation Manual / A150-M56/66/57/67 - A155-M..
15 Taking out of operation at short notice / 15.1 Possible emergency
repairs
© Copyright 2021 ABB. All rights reserved. HZTL4032_EN Rev.Q January 2021
15 Taking out of operation at short notice
15.1 Possible emergency repairs
WARNING
Danger of fire and explosion due to lubricating oil leaks
Leaking oil may ignite on hot surfaces. This can result in serious injuries to
personnel or fatal accidents.
u Cordon off danger area.
u Raise the alarm and, depending on the situation, stop the engine.
u Seal the oil leak.
u Soak up oil and dispose of in an environmentally compatible manner.
Wear safety gloves to protect against thermal hazards.
CAUTION
Directives for taking out of operation
Serious damage to engine or property can be caused by non-compliance
with the directives for blanking the turbocharger off the engine.
u Follow the directives of the enginebuilder.
If the engine has to be operated again as quickly as possible following a turbocharger de-
fect, then the following options are available for emergency repairs:
¡ If present: Installing the replacement turbocharger →166.
¡ If present: Installing the replacement cartridge group →166.
¡ If a replacement turbocharger or cartridge group is not available: Fit cover plate →167
and contact an ABB Turbocharging Service Station.
u Observe the following sections in connection with the emergency repairs mentioned.
Page 165 / 194

Table of Contents

Other manuals for ABB A150-M66

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ABB A150-M66 and is the answer not in the manual?

ABB A150-M66 Specifications

General IconGeneral
BrandABB
ModelA150-M66
CategoryIndustrial Equipment
LanguageEnglish

Related product manuals