Electrical connection
Screw connection:Fine-strand with(out) wire
end ferrule
Connecting capacity
• 1 × 0.5 … 2.5 mm
2
(1 × 18 … 14 AWG)
• 2 × 0.5 … 1.5 mm
2
(2 × 18 … 16 AWG)
Easy Connect Technology (push-in):
• 2 × 0.5 … 1.5 mm
2
(2 × 18 … 16 AWG)
Screw connection:Rigid
• 1 × 0.5 … 4.0 mm
2
(1 × 20 … 12 AWG)
• 2 × 0.5 … 2.5 mm
2
(2 × 20 … 14 AWG)
Easy Connect Technology (push-in):
• 2 × 0.5 … 1.5 mm
2
(2 × 20 … 16 AWG)
8 mm (0.32 in)Stripping length
0.6 … 0.8 Nm (7.08 lbf·in)Tightening torque
Environmental data
-25 °C … +60 °C (-13 °F … +140 °F)OperationAmbient temperature
ranges
-40 °C … +85 °C (-40 °F … +185 °F)Storage
6 x 24 h cycle, 55 °C, 95 % RHDamp heat, cyclic (IEC/EN 60068-2-30)
3K5 (no condensation, no ice formation)Climatic class (IEC/EN 60721-3-3)
5-13.2 Hz: w1 mm; 13.2-100 Hz: 0.7 gVibration, sinusoidal
10 g / 11 msShock
Approvals
ATEX Ex II (2) G D
Isolation data
300 V AC
Supply circuit / Measuring
circuit
1)
Rated insulation voltage U
i
300 V ACSupply circuit / Output
circuits
300 V AC
Measuring circuit
1)
/
Output circuits
300 V ACOutput circuit 1 / Output
circuit 2
4 kV
Supply circuit / Measuring
circuit
1)
Rated impulse withstand
voltage U
imp
4 kVSupply circuit / Output
circuits
4 kV
Measuring circuit
1)
/
Output circuits
4 kVOutput circuit 1 / Output
circuit 2
600 V AC
Supply circuit / Measuring
circuit
1)
Basic insulation
600 V ACSupply circuit / Output
circuits
600 V AC
Measuring circuit
1)
/
Output circuits
300 V ACOutput circuit 1 / Output
circuit 2
56 Technical data