EasyManuals Logo
Home>ABB>Servo Drives>ACS880 Series

ABB ACS880 Series User Manual

ABB ACS880 Series
84 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #62 background imageLoading...
Page #62 background image
IP20Protection degree
Pollution degree 2 & meas. / overvoltage cat. IIInstallation in
Mechanical specifications
109 × 23.5 × 104 mmWithout 4501Dimensions (Height ×
Width × Depth)
109 × 23.5 × 116 mmWith 4501
approximately 185 gWeight
approximately 200 gWeight including 4501
0.13 2.08 mm
2
(AWG 26 14) stranded wireWire sizeTerminals
0.5 N·m (4.4 lbf·in)Tightening torque
±1 mm2 13.2 HzVibration
±0.7 g13.2 100 Hz
Approvals
ATEX Ex II (1) G D
IECEx
EAC Ex
SIL 2 certified according to IEC 61508
For the complete list of approvals, see the relay data sheet.
Isolation data
2.6 kV AC / 300 V AC reinforced isolationTest/working: Input to anyIsolation voltage
2.6 kV AC / 300 V AC reinforced isolationAnalog output to supply
1.5 kV AC / 150 V AC reinforced isolationStatus relay to supply
For the complete relay technical data, see www.prelectronics.com.
General rules, notes and definitions
Validation of the safety functions
You must do an acceptance test (validation) to validate the correct operation of safety
functions.
Competence
The acceptance test of the safety function must be carried out by a competent person with
expertise and knowledge of the safety function as well as functional safety, as required by
IEC 61508-1 clause 6, and ATEX/Ex regulations. The test procedures and report must be
documented and signed by this person.
Validation procedure
You must do the acceptance test using the checklist given in section Start-up and acceptance
test:
at initial start-up of the safety function
after any changes related to the safety function (wiring, components,
safety-function-related parameter settings, etc.)
after any maintenance work related to the safety function.
The acceptance test must include at least the following steps:
you must have an acceptance test plan
you must test all commissioned functions for proper operation, from each operation
location
62 Technical data

Table of Contents

Other manuals for ABB ACS880 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ABB ACS880 Series and is the answer not in the manual?

ABB ACS880 Series Specifications

General IconGeneral
BrandABB
ModelACS880 Series
CategoryServo Drives
LanguageEnglish

Related product manuals