4
Stopping the engine
4.5
Page 54
© Copyright 2016 ABB. All rights reserved.
September 2016 HZTL2410_EN Revision E
Stopping the engine
4.5
CAUTION
Stopping the engine of oil-cooled turbocharger version
Heat in the turbocharger must be dissipated by the further circulating
lubricating oil.
Post-lubricate for 1520 minutes.
Maintain oil pressure of 0.51.0 bar for post-lubrication.
CAUTION
Stopping the engine of water-cooled turbocharger version
Heat in the turbocharger must be dissipated.
Allow turbocharger cooling water to run for 1520 minutes after
stopping engine.
Allow oil lubrication to continue running until rotor comes to a stop.
Further post-lubrication is not required and not recommended.