Malfunctions during operation
6.3
Lubricating oil pressure too low
Engine Oil filter heavily contaminated Clean it
Defective oil pump in lubricat-
ing system
Manometer display wrong Replace the manometer
Rotor axial clearance too large
Contact an ABB Turbocharging
Service Station
Defects of connected cylin-
ders when pulse charging
Contact the enginebuilder
Turbocharger Heavy contamination of the
turbine
Clean it
Damaged rotor components or
bearing
Contact an ABB Turbocharging
Service Station
Pipes Defects such as leaks in the
exhaust gas pipes or charge
air ducts
Make repairs
Turbocharger Heavily contaminated nozzle
ring (with 4-stroke application)
Contact an ABB Turbocharging
Service Station