NOTE
• Material damage due to incorrect cleaning devices.
Damage to the surfaces.
►Do not use any hard, sharp objects.
►Do not use coarse, harsh cleaning devices (e.g.
steel wool)
Cleaning steps during operation:
1. Clean side walls and device frame.
2. If present, clean kick and water protection strips.
3. Clean the glass surfaces outside.
4. Remove food residues, such as spilled liquids,
and packaging waste.
5. Clean the cover runner rail.
6. Dry all cleaned surfaces and parts.
Cleaning steps only with the cooling function
switched off:
1. Move the goods to another device with the same
product temperature class.
2. Switch off the cooling function (see→Chapter
4.2.1, 4.2.2.1, 4.2.3.1) and allow to defrost.
3. Remove the cover (see → Chapter 7).
Clean before reinserting.
Also clean the associated plastic bezels/device
frame and seals. Do not apply large amounts of
cleaning agent to these surfaces to be cleaned.
NOTE
• Material damage due to improper cleaning.
Damage to the surface of plastic bezels/device
frame and impairment of the function of seals.
►There must not be any detergent residues on
the plastic bezels/device frame and seals.
►Always clean plastic bezels/device frame and
seals again with clean water, and dry.
4. Remove all accessory parts from the device
interior, e.g.: air ducts, shelf grille, goods grate.
Clean before reinserting.
5. Remove food residues, such as spilled liquids,
and packaging waste.
6. Cleaning the inside of the device.
For devices with (AD) function:
Clean the defrosting channel.
Lift out and clean the condensation water sieve.
Fig.14 Condensation water sieve
7. Where required, clean the blower fan carrier (see
Fig. 15), for this purpose, fold up and clean the
surface underneath carefully with a damp cloth.
Fig. 15 Blower fan carrier
8. Dry all cleaned surfaces and parts.
9. Correctly reinstall all accessory parts.
10. Correctly reinstall the cover (see → Chapter 7).
11. Clean the floor in front of the device.
1. NOTE
• Property damage from foreseeable misuse.
►The device must only be loaded with goods when
the temperature specified for the product has been
reached.
Maintenance, service and repairs
Responsibility: Qualified staff
The devices are maintenance-free. The service and
repair work, including subsequent functional testing,
must be performed by qualified staff. For questions
about maintenance, please contact the maintenance
service (see → Chapter 10.5.).