EasyManua.ls Logo

ALLIANCE SWNNC2SP115TW01 User Manual

ALLIANCE SWNNC2SP115TW01
90 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #63 background imageLoading...
Page #63 background image
PF rst
DISPLAY TO ENTER IN
STEP 6
POWER FAIL RESET
TIME
oFF *
Turned OFF. Cycle will be
saved.
0 - 120
Number in minutes
0 - 120 minutes without pow-
er before cycle is lost
* Factory default setting.
Table 11
IR Access IrA En
This option allows the owner to enable or disable allowing the
control to be communicated with by an external IR device.
1. Control must be in Manual Mode. Refer to How to Enter the
Manual Mode.
2. Press the DELICATES () or the COLD () keypad until
Prog appears in the display. Press the START (enter) keypad,
and AtS 1 will appear in the display.
3. Press the DELICATES () or the COLD () keypad to scroll
through the programmable options until IrA En appears in
the display.
4.
When IrA En appears in the display, press the START (en-
ter) keypad. The current IR Access status will appear in the
display.
on = Option Enabled (factory default setting)
oFF = Option Disabled
5. Press the DELICATES () or the COLD () keypad to change
the current status.
6. Press the START (enter) keypad when the correct value ap-
pears in the display. The new value is saved and the next op-
tion will appear in the display.
Manual Rapid Advance rAPdEn
This option allows the owner to enable or disable the rapid ad-
vance feature. Refer to Rapid Advance Feature section for more
information.
1. Control must be in Manual Mode. Refer to How to Enter the
Manual Mode.
2. Press the DELICATES () or the COLD () keypad until
Prog appears in the display. Press the START (enter) keypad,
and AtS 1 will appear in the display.
3. Press the DELICATES () or the COLD () keypad to scroll
through the programmable options until rAPdEn appears in
the display.
4.
When rAPdEn appears in the display, press the START (en-
ter) keypad. The current Manual Rapid Advance status will
appear in the display.
0 = oFF (access requires password)
1 = on (access allowed) (factory default setting)
2 = DISABLED (access not allowed)
5. Press the DELICATES () or the COLD () keypad to change
the current status.
6. Press the START (enter) keypad when the correct value ap-
pears in the display. The new value is saved and the next op-
tion will appear in the display.
Manual Diagnostics diAgEn
This option allows the owner to enable or disable the manual di-
agnostics option. Refer to Testing Machine and Electronic Con-
trol Functions section for more information.
1. Control must be in Manual Mode. Refer to How to Enter the
Manual Mode.
2. Press the DELICATES () or the COLD () keypad until
Prog appears in the display. Press the START (enter) keypad,
and AtS 1 will appear in the display.
3. Press the DELICATES () or the COLD () keypad to scroll
through the programmable options until diAgEn appears in
the display.
4.
When diAgEn appears in the display, press the START (en-
ter) keypad. The current Manual Diagnostics status will ap-
pear in the display.
0 = oFF (access requires password)
1 = on (access allowed) (factory default setting)
2 = DISABLED (access not allowed)
5. Press the DELICATES () or the COLD () keypad to change
the current status.
6. Press the START (enter) keypad when the correct value ap-
pears in the display. The new value is saved and the next op-
tion will appear in the display.
Factory Test Ft En
This option allows the owner to enable or disable access to Facto-
ry Test.
1. Control must be in Manual Mode. Refer to How to Enter the
Manual Mode.
2. Press the DELICATES () or the COLD () keypad until
Prog appears in the display. Press the START (enter) keypad,
and AtS 1 will appear in the display.
3. Press the DELICATES () or the COLD () keypad to scroll
through the programmable options until Ft En appears in the
display.
Programming Control
©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT
63 Part No. 204370ENR1

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the ALLIANCE SWNNC2SP115TW01 and is the answer not in the manual?

ALLIANCE SWNNC2SP115TW01 Specifications

General IconGeneral
BrandAlliance
ModelSWNNC2SP115TW01
CategoryWasher
Loading TypeTop Load
ColorWhite
Voltage120V
Frequency60 Hz
Number of Wash Cycles6
Number of Water Levels4
Energy Star CertifiedNo
TypeCommercial

Summary

Safety Warnings

General Safety Precautions

Read instructions before operating. Ensure proper installation and maintenance.

Flammable Vapors Warning

Do not store or use gasoline or other flammable liquids near the appliance.

Model Identification

Preliminary Information

About the Control and Glossary

Overview of control capabilities and definitions of key terms.

Power Failure Recovery

Explains how the control saves cycle status during power interruptions.

Communication Methods

Details Infra-red, Card Reader, and Network communication options.

Control Identification

Select Cycle Pads

Explains how to use cycle selection pads for choosing wash cycles.

Select Wash Temp Pads

Details the use of wash temperature selection pads.

Select Cycle Modifier Pads

Describes the function of cycle modifier pads for advanced options.

Display Identification

Light Emitting Diodes (LEDs)

Explains the purpose of various LEDs for cycle status and selection.

7-Segment Digits

Describes the use of 7-segment digits for displaying time, price, and errors.

Washer Operation

Power Up, Modes, and Start Operations

Covers initial power-up, ready, vend, and start modes.

Cycle Sequence, Signals, and Lid Operation

Details cycle completion, sequence, signals, and lid opening.

Washer Operation (Continued)

Changing Cycles and Delayed Start Setup

Procedure for changing cycles and setting up delayed start.

Operational Modes: Overflow, Lockout, Shutdown

Explains Overflow, Lockout, and Shutdown modes of operation.

Washer Operation (Continued)

Power Failure Display Mode

Describes the display state after an interrupted cycle due to power failure.

Special Features

Programming and Audit Features Overview

Overview of control programming and collecting audit information.

Diagnostics and Communications Features

Running diagnostic tests and using communication modes.

Advance Features and Operations

Explains Rapid Advance, Clear Vend, Coin Drop, and Start Pulse.

Special Features (Continued)

Operational Modes: OPL, Drop-Off, Out of Order

Details OPL, Drop-Off, and Out of Order modes for machine operation.

Special Vend and Shutdown Options

Covers Special Vend, Low Power/Auto-Shutdown, and Error Display.

Network Node and Error Display Modes

Explains Network Node Number display and Error Display modes.

Opening the Service Door

Coin Models Access Procedure

Procedure for opening the service door on coin-operated models.

Card Reader Models Access Procedure

Procedure for accessing the control on card reader models.

Entering the Manual Mode

Manual Mode Navigation Overview

Overview of the five groups within Manual Mode: Programming, Audit, Reset, etc.

Programming Control

Programmable Features Overview

Overview of programmable features like cycle info, vend prices, and special vends.

Programmable Options List Details

Detailed list of programmable options, their display, and factory defaults.

Programming Control (Continued)

Vend Price Configuration (1-4)

Instructions for setting vend prices for Normal Hot, Warm, Cold, and Perm Press.

Programming Control (Continued)

Vend Price Configuration (5-8)

Instructions for setting vend prices for Perm Press Warm/Cold and Delicates.

Programming Control (Continued)

Vend Price 9 and Modifier Pricing

Sets Vend Price 9 and prices for Medium/Heavy cycle modifiers.

Vend Price Decimal Point Setting

Enables decimal point display for vend prices.

Programming Control (Continued)

Coin Values and Start Pulse Settings

Configures coin values and start pulse settings for payment systems.

Programming Control (Continued)

Programmable Output Type Configuration

Programs when the control provides an output signal based on machine status.

Programming Control (Continued)

Default Cycle and Card Reader Display Settings

Sets default cycle and controls card reader display.

Audio Signal Configuration

Configures audio signals for various events like key presses or cycle completion.

Programming Control (Continued)

Audio Signal Table Interpretation Guide

Guides on interpreting the audio signal table for custom settings.

Programming Control (Continued)

Network Node and Error Code Configuration

Sets network node number and enables/disables error codes.

Programming Control (Continued)

Error Code Parameters: Coin, Fill, No Water

Configures parameters for coin, fill, and no water flow errors.

Programming Control (Continued)

Error Code Parameters: Drain, Leak, Overflow

Configures parameters for drain, water leak, and overflow errors.

Programming Control (Continued)

Clock and Daylight Savings Time Configuration

Sets the internal clock and daylight saving time parameters.

Special Vend 1 Day Enable Configuration

Enables or disables Special Vend 1 for specific days of the week.

Programming Control (Continued)

Days Enable Value Table Usage Guide

Table to determine values for Special Vend, Water Leak, and Lucky Cycle day settings.

Programming Control (Continued)

Special Vend 1 Start Time and Date Configuration

Sets start minute, hour, date, and month for Special Vend 1.

Programming Control (Continued)

Special Vend 1 Year, Length, End Date/Month Configuration

Sets start/end year and duration in hours for Special Vend 1.

Programming Control (Continued)

Special Vend 1 Price Configuration (1-5)

Sets vend prices for various cycles under Special Vend 1.

Programming Control (Continued)

Special Vend 1 Price Configuration (6-9) and Agitate Steps

Sets vend prices and adjusts agitate steps for Special Vend 1.

Programming Control (Continued)

Special Vend 1 Cycle Modifier Configuration

Sets default cycle modifier and options for Medium/Heavy keys.

Programming Control (Continued)

Special Vend Days Enable (2-4) Configuration

Enables or disables Special Vends 2, 3, and 4 for specific days.

Cycle Modifier Programming Overview

Programs cycle modifiers like wash time, rinse time, and warm rinse.

Programming Control (Continued)

Cycle Modifier Options and Wash Time

Sets options for Medium/Heavy modifiers and additional wash time.

Programming Control (Continued)

Cycle Modifier Additional Rinse Time

Adds extra rinse time for Medium/Heavy cycles.

Programming Control (Continued)

Cycle Parameters (CYCP) Adjustment

Adjusts wash, rinse, and spin times for various cycle types.

Low Power-Auto Shutdown (1-2) Settings

Enables Low Power/Auto Shutdown for specific days of the week.

Programming Control (Continued)

Low Power-Auto Shutdown (3-4) Settings

Enables Low Power/Auto Shutdown for specific days of the week.

Power Fail Reset Configuration and Table

Configures power failure reset duration and how to read the table.

Programming Control (Continued)

IR Access and Rapid Advance Configuration

Enables/disables IR access and Manual Rapid Advance features.

Manual Diagnostics and Factory Test Configuration

Enables/disables manual diagnostics and factory test access.

Programming Control (Continued)

Lucky Cycle and Water Temp Indicator Settings

Configures lucky cycle features and water temperature indicator.

Programmable Lid Display Settings

Enables/disables close and open lid display messages.

Programming Control (Continued)

Programmable Start/Override Display Settings

Configures push start display and vend price display override.

OPL Parameters and Mode Settings

Enables OPL mode, delayed start, and display power save.

Programming Control (Continued)

OPL Delayed Start and Power Save Settings

Configures OPL delayed start and display power save features.

Drop Off Mode Configuration

Limits machine use to attendant without requiring vend.

Programming Control (Continued)

Out of Order Mode Configuration

Disables machine use by displaying an out of order message.

Collecting Audit Information

Audit Feature Entry Methods

Methods to enter the audit feature via manual mode or coin vault.

Reading and Exiting Audit Data

Procedure to read audit data and exit the audit feature.

Manual Reset

Manual Reset Entry Procedure

Steps to reset the control to factory default settings.

Testing Machine and Electronic Control Functions

Diagnostic Feature Entry

Procedure to enter the diagnostic testing mode.

Starting and Exiting Diagnostic Tests

Instructions for initiating and exiting diagnostic tests.

Diagnostic Mode Quick Reference Chart

Chart listing test numbers, modes, and expected display outputs.

Diagnostic Test Descriptions

Software Version and Switch Input Tests

Tests for control/board software versions and door/vault/coin switches.

Coin Drop, Vend Header, and Start Pulse Tests

Tests for coin drop inputs, vend header connection, and start pulse.

Lid Switch and Fill/Drain Time Tests

Tests for lid status and average fill/drain times.

Diagnostic Test Descriptions (Continued)

External Output, Water Purge, Leak, Level Tests

Tests for external outputs, water purge, leaks, and water level.

Diagnostic Test Descriptions (Continued)

Configuration Display Tests Overview

Shows machine configuration values and dipswitch settings.

Diagnostic Test Descriptions (Continued)

Configuration Display Tests (Continued)

Shows machine configuration values and dipswitch settings.

Diagnostic Test Descriptions (Continued)

Configuration Display Tests (Continued)

Shows machine configuration values and dipswitch settings.

Factory Test

Factory Test Entry Procedure

Procedure to enter Factory Test mode using specific keypad combinations.

Factory Test Quick Reference Chart

Reference chart for displays, test modes, and comments during factory testing.

Error Codes

External Device Communication Errors

Error codes related to Infra-red and card reader communication failures.

Machine and Payment System Error Codes

Error codes for machine operation, payment systems, and invalid data.

Error Codes (Continued)

Card Communication and ID Error Codes

Codes for card reader issues, network communication, and machine ID.

System and Board Error Codes

Codes for fill, coin, board ID, brownout, and drive/output board issues.

Error Codes (Continued)

Data Mismatch and Drain Error Codes

Codes for product byte mismatches, communication, drain, and slow drain errors.

Error Codes (Continued)

Flow, Pressure, and Thermal Error Codes

Codes for no flow, overflow, pressure sensor, and thermal protection errors.

Rapid Advance Feature

Rapid Advance Operation Guide

Instructions for quickly advancing through cycles for testing or operation.

Clear Vend Feature

Clear Vend Procedure

Procedure to reset the control to ready mode when vend price is partially met.

Power Fail Recovery

Communications Mode

Infra-red and Card Reader Communications

Details Infra-red and Card Reader communication features.

Network Communications Explanation

Explains how the control communicates via a network.

Default Cycle Time

Related product manuals