#6001 COMBITHERM ELECTRIC INSTALLATION AND MAINTENANCE MANUAL
PG. 4
POSITIONING ON SITE
Before removing the oven from the pallet for positioning on
site, it is important to remove the drip tray to prevent
damage to the tray caused by the lifting forks. The drip tray
is fastened to the bottom of the oven with three sheet metal
screws as illustrated. This requirement pertains to the
following models.
This step does not
pertain to models
12•20ML and 20•20ML.
Lift the oven from the pallet with a fork lift or
pallet lift truck positioned at the front of the
oven. To avoid damage, position the lift forks to
the left of the condenser as indicated in one of
the two diagrams shown below. For additional
damage protection, the use of two wooden
boards, placed between the bottom of the oven
and the lifting forks, is strongly recommended.
After the oven is correctly positioned on site,
reattach the drip tray.
MODEL
6•10
10•10
7•14
10•18
12•20
20•20
NET WEIGHT
285 lb (129 kg)
385 lb (175 kg)
405 lb (184 kg)
514 lb (233 kg)
665 lb (302 kg)
958 lb (435 kg)
15"
(381mm)
MODELS
6•10
10•10
7•14
10•18
CONDENSER
10"
(254mm)
3"
(76mm)
8"
(203mm)
CONDENSER
MODELS
12•20
20•20
MODELS 6•10ML
10•10ML
7•14ML
10•18ML
COMBITHERM
®
INSTALLATION
➤
OBSERVE ATTENTION LABEL ON OVEN FOR
AREA TO AVOID WITH LIFTING FORK
.