C139603300_2.fm
- 15 -
IT
AUS
DE
FR
ES
GAS CONNECTION
To make the connection, connect the mains line to the
appliance's connection pipe, fitting a shut-off tap (A),
to allow the gas supply to be cut off when neces-
sary.This appliance shall be installed only by author-
ised personnel and in accordance with the
manufacture’s installation instructions, local gas fit-
ting regulations, municipal building codes, water sup-
ply regulations, electrical wiring regulations, AS
5601/AG 601 - Gas Installations and any other statu-
tory regulations.
Important
The tap (A), not supplied with the appliance,
must be installed in an easily accessible
position and its status (on or off) must be
obvious at a glance.
ELECTRICAL CONNECTION
Important
The connection must be made by author-
ised, skilled personnel, in accordance with
the relevant legal requirements, using ap-
propriate and specified materials.
Caution - warning
Before doing any work, cut off the mains elec-
tricity supply.
Connect the appliance to the mains electricity supply
as follows.
1 - If not already present, install a circuit-breaker (A)
with overload cutout and differential safety break-
er close to the appliance.
2 - Open the hatch (B).
3 - Undo the screws (C) to remove the lid (D).
4 - Connect the circuit-breaker (A) to the terminal
board (E) of the appliance as shown in the dia-
gram and in the electrical system diagram at the
back of the manual.
N.B.: use cable with at least H05RN-F characteristi-
cs.,
5 - Replace the lid (D) and retighten the screws (C)
on completion of the operation.
Important
When connecting, take care over the con-
nection of the neutral and earth lines; if
they are not connected correctly, the burn-
er does not light.
A
IDM-3960200230.tif
B
C
A
CDC
IDM-39603311900.tif
E