10 11
Event Event designator Start time
Setpoint
Heat Cool
1 WAKE 6:00AM 70°F (21°C) 78°F (25.5°C)
2 LEAVE 8:00AM 62°F (16.5°C) 85°F (29.5°C)
3 RETURN 5:00PM 70°F (21°C) 78°F (25.5°C)
4 SLEEP 10:00PM 62°F (16.5°C) 82°F (27.5°C)
OPERATION & PROGRAMMING
UNDERSTANDING PROGRAM SCHEDULES (CONTINUED)
PROGRESSIVE RECOVERY
The Progressive Recovery feature allows the thermostat
to activate the heating and cooling equipment prior to
an event in order to reach the desired temperature at
the start of the next scheduled event.
Example:
Set the Wake time to 6 am, and the heat setpoint
to 70°F. The heat will come on before 6 am, so the
temperature is 70°F by the time you wake at 6 am.
CHANGING PROGRAM SCHEDULES
OPERATION & PROGRAMMING
1. Press twice to enter program setting mode.
Start time of the WAKE event is flashing.
2. Press
or to adjust the start time
3. Press
, HEAT setting flashes. Press or
to adjust the heat setting.
4. Press , COOL setting flashes. Press or
to adjust the cool setting.
5. Press
, CLEAN AIR/FAN setting flashes. Press
or to adjust the clean air/fan setting.
6. Press
to advance the next event, and repeat
steps 2-6 for LEAVE, RETURN and SLEEP events.
7. Press
to advance to the next day. Repeat
steps 2-6 for each day of the week.
8. Press
to end. “DONE” will display.
The thermostat will return to normal mode if no button
is pressed in 3 seconds.