use and maintenance Area 51
&+(&.,1* $1' &/($1,1* 7+(
7(50,1$/6
Carefully read p. 49 (BATTERY).
Remove the rear inspection cover, see
p. 46 (REMOVING THE REAR INSPEC-
TION COVER).
Make sure that the cable terminals (1)
and the battery terminals (2) are:
in good conditions (and not corroded
or covered with deposits);
covered with special grease or Vase-
line.
If necessary:
Make sure that the ignition switch is in
position “
”.
Disconnect first the negative (–) and then
the positive cable (+).
Brush with a wire brush to eliminate any
sign of corrosion.
Reconnect first the positive (+) and then
the negative cable (–).
Cover the terminals with special grease
or Vaseline.
5(029,1* 7+( %$77(5<
Carefully read p. 49 (BATTERY).
Remove the rear inspection cover, see
p. 46 (REMOVING THE REAR INSPEC-
TION COVER).
Make sure that the ignition switch is in
position
”.
Disconnect first the negative (–) and then
the positive cable (+).
Remove the battery breather pipe.
Remove the battery from its compart-
ment and put it on a flat surface, in a cool
and dry place.
Once it has been removed, the
battery must be stored in a safe
place and kept away from chil-
dren.