12.1. Device
12.1. Device12.1. Device
12.1. Device
Select the appropriate device type from the drop down list. This setting will deter-
mine how sensor readings are processed internally and which settings will be avail-
able. If not set correctly, proper operation will not be possible!
If not set correctly, proper operation will not be possible!If not set correctly, proper operation will not be possible!
If not set correctly, proper operation will not be possible! The following table
shows the correct assignment of article numbers and device type selection:
Article number
Article numberArticle number
Article number Device type
Device typeDevice type
Device type
34041, 34042, 34050, 34058,
34059, 34060, 34061, 34066,
34067, 34068, 34069, 34072
Fill level sensor ∆40
41093 D5 pump
41095, 41097, 41099, 41101 Fill level sensor ∆40
53129 Flow sensor high flow USB
53130, 53131, 53132 Flow sensor mps flow
53133 Pressure sensor ∆40 or
oror
or
fill level sensor
∆40 depending on usage
53134 Pressure sensor ∆100 or
oror
or fill level sensor
∆100 depending on usage
53135 Pressure sensor ∆500 or
oror
or
fill level sensor
∆500 depending on usage
53136, 53160 Pressure sensor 1000 or
oror
or
fill level sensor
1000 depending on usage
12.2. Sensor configuration flow sensor mps flow
12.2. Sensor configuration flow sensor mps flow12.2. Sensor configuration flow sensor mps flow
12.2. Sensor configuration flow sensor mps flow
The flow sensors of the mps flow 100/200/400 sensors are based upon a differ-
ential pressure measurement around a nozzle element that is greatly affected by
installed fittings and hoses. Please start by selecting the sensor type, then select the
type of fittings you have installed into the sensor. Confirm your selection by click-
ing “Import calibration data”.
For accurate flow measurement, the zero flow value must be calibrated regularly,
therefore “Automatic calibration of zero flow” is activated by default. If activated,
the sensor will perform a calibration of the zero flow value when the pump is not
running, for example if the PC is in standby and the sensor is still powered by USB
- 18 - Aqua Computer GmbH & Co. KG © 2012-2016
Gelliehäuser Str. 1, 37130 Gleichen
c
o
m
p
u
t
e
r
a
q
u
a

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Aqua Computer mps flow 100 and is the answer not in the manual?

Aqua Computer mps flow 100 Specifications

General IconGeneral
BrandAqua Computer
Modelmps flow 100
CategoryWater Dispenser
LanguageEnglish

Related product manuals