Power supply voltage (USB/aquabus): 5 V DC
Power supply current: ca. 50 mA
Maximum current alarm output: 100 mA, max. 30 V
Maximum pressure (pressure sensors): 1 bar / 100 kPa
Connection threads pressure sensors: M5
Connection threads flow sensors: G1/4
Measuring range temperature sensor input: -35 to 100 °C
Ambient temperature range: 10 to 50 °C (noncondensing)
16.2. D5 pump motor
16.2. D5 pump motor16.2. D5 pump motor
16.2. D5 pump motor
Power supply voltage: 8-24 V DC
Power consumption: max. 37 W
Maximum current alarm output: 100 mA, max. 30 V
Measuring range temperature sensor input: -35 to 100 °C
Maximum coolant temperature: 60 °C
Ambient temperature range: 10 to 50 °C (noncondensing)
16.3. Care instructions
16.3. Care instructions16.3. Care instructions
16.3. Care instructions
Use a dry and soft cloth for cleaning. All electronic components and headers must
not get in contact with coolant or water!
16.4. Waste disposal
16.4. Waste disposal16.4. Waste disposal
16.4. Waste disposal
This device has to be disposed of as electronic waste. Please check
your local regulations for disposal of electronic waste.
17. Contact Aqua Computer
17. Contact Aqua Computer17. Contact Aqua Computer
17. Contact Aqua Computer
We are always happy to answer questions regarding our products and to receive
feedback. For answers on frequently asked questions, please also check our web-
site www.aqua-computer.de. You might also want to visit our forums and discuss
our products with experienced moderators and thousands of members – available
24/7. To get in direct contact with our customer support team, we offer several
options:
email: support@aqua-computer.de
Address: Aqua Computer GmbH & Co. KG
Gelliehäuser Str. 1
- 22 - Aqua Computer GmbH & Co. KG © 2012-2016
Gelliehäuser Str. 1, 37130 Gleichen