COMMISSIONING
/ 37
G20 20 mbar
G230 20 mbar
G30 - G31 28/37 mbar
WARNING!!
THE AUTOMATIC CALIBRATION MUST BE DONE IN
CASE OF:
- REPLACEMENT OF: FAN, GAS VALVE, AIR/GAS
MIXER, BURNER, ELECTRODE.
- REPLACEMENT OF P.C.B.
- GAS CHANGEOVER
- ANY MODIFICATION TO THE FOLLOWING
PARAMETERS
220 - SOFT IGNITION
231 - MAX CH ADJUSTABLE
232 - MAX DHW PERCENTAGE
233 - MIN PERCENTAGE
234 - MAX CH PERCENTAGE
Example: Boiler adjusted for LPG
4
Gas
MAX
MIN
Gas
mbar
mbar
Gas Changeover
The boiler is factory setted for the gas type indicated on the
data plate. The adjustment, if necessary, must be performed
by a Qualied Technician. It is not necessary a conversion kit,
because the boiler has a auto adaptation gas system.
Proceed as indicated:
1. Change parameter 202 to the new gas (see Technical Area).
The display shows the error “The boiler must be calibrated”.
2. Turn the screw to position 2 on the gas valve
3. Perform the Atomatic Calibration and the CO
2
calibration as
indicated from page 18 to page 21.
Note: If the automatic calibration is not performed, the
system will perform the calibration during the rst ignition.
4. At the end apply the new label (supplied with the product),
as shown in the gure, indicated the new gas type used.
5. Verify and repair any leaks of gas.