Enter settings
1. Keep the F1 pressed.
2.
Press the Reset button until the buzzer sounds and the LED F1 =
3. Release the F1 button.
4.
Batch Number setting (LED F1= ) is now selected. To select a different setting, press the F1 but-
ton repeatedly according to the Main settings table.
5. Set the setting value by pressing the F2 and F3 buttons.
6. Repeat Step 4 and 5 until all settings are correct.
7.
Exit settings by keeping the F1 button pressed until buzzer sounds twice and LED F1 =
Main setting table
Setting Description LED F1 LED F2 and F3
Batch number Set the number of screws
in the batch
1 - 99 screws
Re-hit timer Set the time before a new
tightening can be made
and thereby disabling re-
hits of screws.
0.00 - 0.99 s
Tool Disable Timer 1 Set a pause timer that
starts as soon as the
“SET” signal is given as
an input. The timer also
generates the valve out-
put signal that can be
used to lock the work-
piece. When time is up
the screwdriver returns to
normal operation.
0.0 - 3.9 s
Tool Disable Timer 2 Set a pause timer after
the end of the batch (end
of the VALVE-signal).
When time is up, the
screwdriver returns to nor-
mal operation.
0.0 - 3.9 s