114
Instruction book
9096 3313 00
• (A): Air inlet temperature
• (B): Condensation temperature
• (C): Working pressure
• (D): Relative air humidity
Example: If operating at a pressure of 10 bar(e) in an ambient temperature of 20 °C and at a relative air
humidity of 100%, the minimum temperature to prevent condensate from forming is 68 °C . Regulate the cooling
water flow during loaded operation to obtain a temperature between 70
0
Cand approx. 75 °C at the outlet of the
compressor element.
7.5 During operation
Warnings
Checking the oil level
Control panel Elektronikon Graphic
The operator must apply all relevant Safety precautions. Also consult section
Problem solving.
Keep the doors closed during operation; they may be opened for short periods only to
carry out checks.
When the motors are stopped and LED (8) (automatic operation) is alight, the motors
may start automatically.
When the automatic operation LED (8) is lit, the regulator is automatically controlling the
compressor, i.e. loading, unloading, stopping of the motors and restarting!.