Instruction book
9096 3313 00
service plan interval has been exceeded or if a service level for a monitored component has been exceeded.
Carry out the service actions of the indicated plans or replace the component and reset the relevant timer, see
section Service menu.
7.7 Stopping
Elektronikon regulator
Procedure
7.8 Taking out of operation
Warning
Control panel Eledtronikon Graphic
Step Action
-
Press stop button (9). Automatic operation LED (8) goes out and the compressor stops after
30 seconds of unloaded operation.
-
To stop the compressor in the event of an emergency, press emergency stop button (10).
Alarm LED flashes (7).
On compressors with an Elektronikon® Graphic controller:
Remedy the fault and unlock the button by pulling it out.
Navigate to the Stop icon on the display by means of the navigation keys (3/4) and
press the Select key.
Press reset.
Do not use emergency stop button (10) for normal stopping! See also section
Emergency stop button .
- Close air outlet valve (AV), see section Introduction.
-
On water-cooled compressors:
Close the cooling water inlet valve.
If freezing temperatures can be expected, drain the cooling system completely.
The operator must apply all relevant Safety precautions.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Atlas Copco ga55+ and is the answer not in the manual?

Atlas Copco ga55+ Specifications

General IconGeneral
ModelGA55+
CategoryAir Compressor
Working Pressure7.5 bar
Motor Power55 kW
Noise Level69 dB(A)
Cooling SystemAir-cooled
Drive TypeDirect Drive
Free Air Delivery10.2 m³/min

Related product manuals