Instruction book
9096 3313 00
OSCi service kit
1 Oleophilic filter
2 Buckets (can be used to receive the used filters after maintenance)
3 OGC filter
4 Gloves
5 Activated carbon filter
part number Filter kit OSCi:................................................................................................2901 1734 00
Condition Fault Remedy
1 A lot of oil entered the OSCi. Compressor malfunctioning
Replace all filters. Clean the vessels.
Check the compressor.
2
The Elektronikon® gives
overflow warning, or visible
overflow (sight-glass).
A section of the outlet tube is
higher than the corresponding
outlet connection.
Reposition the outlet tube to below
the outlet connection level (View of
OSCi outlet) (check inside and
outside the compressor).
A filter is saturated. Replace filters and clean the OSCi
Injected airflow too high Replace strainer (4-OSCi air injection).
4.10 Problem solving
4.9 Service kits
Your Atlas Copco Customer Centre will be glad to provide you with a wide range of service kits. Service
kits comprise all parts needed for servicing components and offer the benefits of genuine Atlas Copco parts
while keeping the maintenance budget low.