11. Pour clean water along the inner edge of vessel 1 until water flows out of the outlet tube (1-View of
OSCi outlet), or until the water reaches the bottom of the sensor chamber (visible through the sight-
glass). The oleophilic filter will start to float. Do not push the filter down.
12. Put the cover back on the vessel and tighten the clamping ring.
13. Close/reposition the compressor bodywork.
14. Reset the service counter of the Elektronikon®. See section Elektronikon Warnings.
• If the filters are not installed properly, oil-containing condensate can leave the OSCi.
• When placing new activated carbon filters, the outgoing water may initially look black (car
bon dust). The carbon water is not harmful.
• All filters, oil-containing tissues and water must be disposed of in an environmentally
friendly and safe manner and in line with the local recommendations and environmental
legislation.
• Each new filter is provided with a label. The correct position is marked on the label.
• Used filters can be heavy
• See to it that no condensate comes into contact with eyes, mouth, …
• If the compressor has not been in operation during a long period, bacteria formation could
occurin side the OSCi. Depending on the amount of bacteria it is advised to clean the OSCi
before putting the compress or back into operation.