Maximum air inlet temperature ˚F 115
Minimum ambient temperature ˚C 0
Minimum ambient temperature ˚F 32
8.4 Compressor data
50 Hz 7.5-13 bar (under reference conditions)
Compressor type GX7 GX11 GX7 GX11 GX7 GX11
Frequency Hz 50 50 50 50 50 50
Maximum
(unloading)
pressure, Pack
bar(e) 7.5 7.5 10 10 13 13
Maximum
(unloading)
pressure, Pack
psig 109 109 145 145 189 189
Maximum
(unloading)
pressure, Full-
Feature
bar(e) 7.25 7.25 9.75 9.75 12.75 12.75
Maximum
(unloading)
pressure, Full-
Feature
psig 105 105 141 141 185 185
Nominal working
pressure
bar(e) 7 7 9.5 9.5 12.5 12.5
Nominal working
pressure
psig 102 102 138 138 181 181
Set-point,
thermostatic valve
˚C 75 75 75 75 75 75
Set-point,
thermostatic valve
˚F 167 167 167 167 167 167
Temperature of air
leaving outlet valve
(approx.), Pack
•
Tank-mounted
˚C 38 43 38 43 38 43
•
Tank-mounted
˚F 100 109 100 109 100 109
•
Floor-mounted
˚C 61.5 65 61.5 65 61.5 65
•
Floor-mounted
˚F 143 149 143 149 143 149
Temperature of air
leaving outlet valve
(approx.), Full-
Feature
˚C 25 26 25 26 25 26
Temperature of air
leaving outlet valve
(approx.), Full-
Feature
˚F 77 79 77 79 77 79
Instruction book
66 2920 7054 00