- 80 -
COMPRESSOR / ENGINE SPECIFICATIONS
REFERENCE CONDITIONS
The inlet conditions are specified at the air inlet grating outside the canopy.
LIMITATIONS
Designation Unit U190 PACE
Absolute inlet pressure bar 1
psi 14.5
Relative air humidity % 0
Air inlet temperature °C 20
°F 68
Normal effective working pressure bar 10.5
psi 152.3
Designation Unit U190 PACE
Minimum effective receiver pressure bar 3
psi 43.5
Maximum effective receiver pressure, compressor unloaded bar 11.5
psi 166.7
Maximum ambient temperature at sea level 5) °C 50
°F 122
Minimum starting temperature °C -10
°F 14
Minimum starting temperature, with coldstart equipment °C -20
°F -4
Altitude capability m 3000