AIR FILTER ENGINE/COMPRESSOR
CLEANING THE DUST TRAP
To remove dust from the dust trap squeeze the
vacuator valve (5) several times.
CLEANING
CLEANING COOLERS
Keep the coolers clean to maintain the cooling
efficiency. Open the hood and clean the coolers with
a fibre brush and compressed air.
Steam cleaning in combination with a cleansing agent
may be applied.
CLEANING HARDHAT
Optimal cleaning of the HardHat can be achieved by
high pressure cleaning in combination with liquid
soap.
1. Snap clips 5. Vacuator valve
2. Dust trap cover 6. Vacuum indicator
3. Filter element 7. Reset button
4. Filter housing 8. Yellow indicator
(1)
(5)(2) (3) (4)
(6)
(8)
(7)
Remove any dirt from the coolers with a
fibre brush. Never use a wire brush or
metal objects.
To avoid damaging the coolers, angle
between jet and coolers should be
approx. 90 °.
Protect the electrical and controlling
equipment, air filters, etc. against
penetration of moisture.
Never leave spilled liquids such as fuel,
oil, water and cleansing agents in or
around the compressor.
Do not use water with a temperature
>50°C (122°F).
Box_2-2.book Page 35 Friday, October 27, 2017 3:48 PM

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Atlas Copco XAHS 70 KD8 WUX and is the answer not in the manual?

Atlas Copco XAHS 70 KD8 WUX Specifications

General IconGeneral
BrandAtlas Copco
ModelXAHS 70 KD8 WUX
CategoryAir Compressor
LanguageEnglish

Related product manuals