3.4.5 Connecting MP-124 to Power
MP-124 can be powered either from a standard AC electrical outlet or a 48-VDC power
supply. The power configuration depends on the ordered MP-124 model.
After powering-up MP-11x, the Ready and Power LEDs on the front panel light up green
(after a self-testing period of about two minutes). Any malfunction in the startup procedure
changes the Fail LED to red and the Ready LED is turned off.
3.4.5.1 AC Power Supply
This section describes cabling of the MP-124 model for AC power.
Warnings:
• The device must be connected only by professional service personnel.
• Ensure that the device connects to an electrical socket outlet that
provides protective earthing (grounding). Prior to connecting power, refer
to the Regulatory Information document supplied with the device.
• Use only the AC power cord supplied with the device.
To connect MP-124 to the AC power supply:
1. Connect the line socket of the AC power cord (supplied) to the device's AC power
socket (labeled 100-250 V~50 - 60Hz 2A), located on the rear panel.
Figure 3-13: AC Power Cabling
2. Connect the plug at the other end of the AC power cord to a standard electrical outlet.