J-9
LCD Display Counter/Timer
(A)
Photoelectric
Sensors
(B)
Fiber
Optic
Sensors
(C)
Door/Area
Sensors
(D)
Proximity
Sensors
(E)
Pressure
Sensors
(F)
Rotary
Encoders
(G)
Connectors/
Connector Cables/
Sensor Distribution
Boxes/Sockets
(H)
Temperature
Controllers
(I)
SSRs / Power
Controllers
(J)
Counters
(K)
Timers
(L)
Panel
Meters
(M)
Tacho /
Speed / Pulse
Meters
(N)
Display
Units
(O)
Sensor
Controllers
(P)
Switching
Mode Power
Supplies
(Q)
Stepper Motors
& Drivers
& Controllers
(R)
Graphic/
Logic
Panels
(S)
Field
Network
Devices
(T)
Software
Specications
※
1: This is for the voltage input (PNP)/no-voltage input (NPN) selectable model (CX6 - ).
※
2: The weight includes packaging. The weight in parenthesis is for unit only.
※
Environment resistance is rated at no freezing or condensation.
Model CX6S-1P
CX6S-2P
CX6M-1P
CX6M-2P
Display digits 6-digit
Display method
7-segment (1st, 2nd digits of counting value display: white, setting value display: green) LCD method,
11-segment (the other digits of counting value display: white) LCD method,
Operation display part: yellow LCD method
Character
size (W×H)
Counting value 4.1×10.1mm 6.2×15.2mm
Setting value 3. 3×8.1mm 5×12.3mm
Power
supply
AC voltage 100-240VACᜠ 50/60Hz
AC/DC voltage 24VACᜠ 50/60Hz, 24-48VDC
ᜡ
Permissible voltage range 90 to 110% of rated voltage
Power
consumption
AC
voltage
CX6 - Max. 6.4VA Max. 6.7VA Max. 7.1VA Max. 7.5VA
CX6 - F Max. 4.2VA Max. 4.9VA Max. 4.7VA Max. 5.4VA
AC/DC
voltage
CX6 -
AC: max. 5.5VA
DC: max. 3.5W
AC: max. 5.6VA
DC: max. 3.6W
AC: max. 6.2VA
DC: max. 4W
AC: max. 6.3VA
DC: max. 4.1W
CX6 - F
AC: max. 3.6VA
DC: max. 2.5W
AC: max. 4.0VA
DC: max. 2.8W
AC: max. 3.9VA
DC: max. 2.9W
AC: max. 4.5VA
DC: max. 3.3W
Counter
Max. INA/
INB counting
speed
CX6 - Selectable among 1cps/30cps/300cps/1kcps/5kcps
CX6 - F 20cps
Counting range -99999 to 999999
Scale Decimal point up to fth digit
Min. signal
width
CX6 - RESET, TOTAL RESET signal: selectable among 1ms/20ms
CX6 - F RESET signal: 25ms
Timer
Time range
999.999s, 9999.99s, 99999.9s, 999999s, 99m59.99s, 999m59.9s, 9999m59s, 99999.9m, 999999m,
99h59m59s, 9999h59m, 99999.9h
Operation mode Up, Down
Min. signal
width
CX6 - INA, I NHIBIT, RESET, TOTAL RESET signal: selectable among 1ms/20ms
CX6 - F INA, INH, RESET signal: 25ms
Repeat error
[CX6 - ]- In case of power ON start: max. ±0.01% ±0.05s
In case of signal ON start: max. ±0.01% ±0.03s
[CX6 - F]- In case of power ON start: max. ±0.01% ±0.08s
In case of signal ON start: max. ±0.01% ±0.06s
Set error
Voltage error
Temp. error
Input method
CX6 -
Selectable among voltage input (PNP)/no-voltage input (NPN)
[Voltage input (PNP)]-input impedance: 10.8kΩ, [H]: 5-30VDC
ᜡ
, [L]: 0-2VDC
[No-voltage input (NPN)]-short-circuit impedance: max. 1kΩ, short-circuit residual voltage: max. 2VDC
CX6 - F
[Free voltage input]- INA (START) , INB (INHIBIT) input
[H]: 24-240VDC
ᜡ
/24-240VACᜠ
50/60Hz, [L]: 0-10VDC/VAC
[No-voltage input]- RESET input, short-circuit impedance: max. 1kΩ, short-circuit residual voltage: max. 2V
One-shot output time 0.01 to 99.99s setting
Control
output
Contact
Type SPDT (1c): 1 SPST (1a): 2 SPDT (1c): 1 SPDT (1c): 2
Capacity Max. 250VACᜠ 3A, 30VDC
ᜡ
3A resistive load
Solid
state
Type
-
NPN open collector: 1 NPN open collector: 2
Capacity Max. 30VDC
ᜡ
100mA
External power supply
※
1
Max. 12VDC
ᜡ
±10%, 100mA
Memory retention Approx. 10 years (non-volatile memory)
Insulation resistance Over 100MΩ (at 500VDC megger)
Dielectric strength 3,000VAC 50/60Hz for 1 min
Noise
immunity
AC voltage Square-wave noise by noise simulator (pulse width 1
㎲
) ±2kV
AC/DC voltage Square-wave noise by noise simulator (pulse width 1
㎲
) ±500V
Vibration
Mechanical 0.75mm amplitude at frequency 10 to 55Hz (for 1 min) in each X, Y, Z direction for 1 hour
Malfunction 0.5mm amplitude at frequency 10 to 55Hz (for 1 min) in each X, Y, Z direction for 10 minutes
Shock
Mechanical 300m/s² (approx. 30G) in each X, Y, Z direction for 3 times
Malfunction 100m/s² (approx. 10G) in each X, Y, Z direction for 3 times
Relay life
cycle
Mechanical Min. 5,000,000 operations
Malfunction Min. 100,000 operations
Protection structure Front part: IP50 (IEC standard)
Environ-
ment
Ambient temp. -10 to 55
℃
, storage: -25 to 65
℃
Ambient humi. 35 to 85%RH, storage: 35 to 85%RH
Approval
Weight
※
2
AC voltage
CX6 -
Approx. 157g (approx. 112g) Approx. 162g (approx. 117g) Approx. 235g (approx. 170g) Approx. 240g (approx. 175g)
CX6 - F
Approx. 155g (approx. 110g) Approx. 160g (approx. 115g) Approx. 233g (approx. 168g) Approx. 238g (approx. 173g)
AC/DC
voltage
CX6 -
Approx. 156g (approx. 111g) Approx. 161g (approx. 116g) Approx. 234g (approx. 169g) Approx. 239g (approx. 174g)
CX6 - F
Approx. 154g (approx. 109g) Approx. 159g (approx. 114g) Approx. 232g (approx. 167g) Approx. 237g (approx. 172g)