Unit Description
1. Counting value display component (white)
RUN mode: Displays counting value for counter operation or time progress value for timer operation.
Function setting mode: Displays parameter.
2. Setting value display component (green)
RUN mode: Displays setting value.
Function setting mode: Displays parameter setting value.
3. Time unit indicator (h:m:s):
Turns ON for time unit for timer.
4. Key lock indicator ( ):
Turns ON for key lock setting.
5. Reset input indicator (RST):
Turns ON for reset key input or reset signal input.
6. INH indicator (INH)
For
the voltage input (PNP)/no-voltage input (NPN) selectable model
(CX6 - ), it turns ON for INHIBIT signal input.
(In case of CX6S Series and timer mode, it turns ON for INB/INH signal input.)
For free voltage input model (CX6
-
F), it turns ON for INB/INH signal input for timer.
7. Output indicator (OUT1, OUT2):
Turns ON for the dedicated control output ON.
8. SV checking and changing indicator (SET, SET1, SET2) (green):
Turns ON when checking and changing SV.
9. COUNTER indicator (COUNTER):
Turns ON for counter operation.
10. TOTAL
indicator
※
1
(TOTAL):
In case of TOTAL counter display mode, it turns ON with the COUNTER indicator.
11. TIMER indicator (TIMER):
Flashes (progressing time) or Turns ON (stopping time) for timer operation.
12.
RESET
key
RUN mode, Function setting mode: Press the
RESET
key to reset the counting value and turn OFF the output.
TOTAL counter display mode
※
1
: Press the
RESET
key to reset the counting value of TOTAL counter.
13. key
RUN mode: Hold the
key over 3 sec to enter function setting mode.
Press the
key to select SV2 (SET2)/SV1 (SET1)/TOTAL counter
※
1
display for counter operation.
Function setting mode: Hold the key over 3 sec to return RUN mode.
Press the key to save the SV and enter the next setting.
Function setting check mode: Hold the key over 1 sec to return RUN mode.
Changing SV mode: Press the key to save SV and return RUN mode.
14.
,
key
1) key
RUN mode: Press the key to change SV and move SV (SET, SET1, SET2) digits.
Changing SV mode: Press the key to change digits.
2) key
Changing SV mode: Increases SV.
Function setting mode: Changes the settings.
※
1: This is for the voltage input (PNP)/no-voltage input (NPN) selectable model (CX6 - ).