Pressure Sensor
< When Auto shift is used >
Flashing twice when
input Auto shift signal
Time
Min. 1ms
Time
Time
Preset point value will be
corrected by Auto shift input.
Min. 7.5ms
(Switch output
Response time
when Auto shift signal is input)
Switch
output
response
Auto shift
input
< When Auto shift is not used >
▶
When Auto shift function is used
※
When Auto shift function is used, the possible set pressure
range will be wider than rated set pressure range.
※
The possible set pressure range for Auto shift type
models.
※
If the set point value corrected by auto shift input exceeds
set pressure range,an error message will flash three times
and corrected value is not saved.
→[
-HH-
] displayed when the set point value corrected by
Auto shift input is above the upper limit of set pressure
range.
→ [
-LL-
] displayed when the set point value corrected
by Auto shift input is below the lower limit of set pressure
range.
※
The correction value will be saved in EEPROM.
Pressure
type
Set pressure range
Possible set pressure range
for Auto shift type models
Vacuum
pressure
-101.3kPa to 5.0kPa -101.3kPa to 101.3kPa
Vacuum
pressure
-5.0kPa to 110.0kPa -110.0kPa to 110.0kPa
-50.0kPa to 1100kPa -1100kPa to 1100kPa
Compound
pressure
-101.3kPa to 110.0kPa -101.3kPa to 110.0kPa
Error
display
Description Troubleshooting
ERR1
When external pressure is
input while adjusting zero
point
Try again after removing
external pressure
ERR2
When overload is applied on
control output
Remove overload
ERR3
When setting condition is not
met in Auto sensitivity setting
mode
Check setting conditions and
set proper setting values
LLLL
When applied pressure
exceeds Low-limit of display
pressure range
Apply pressure within display
pressure range
HHHH
When applied pressure
exceeds High-limit of display
pressure range
-HH-
-LL_
-HO_
Auto shift correction error
Set the corrected setting
value within setting pressure
range.
Auto shift input
Reference pressure =
Atmospheric pressure
(0.0kPa)
Reference pressure ≤
Atmospheric pressure
(0.0kPa)
Reference pressure ≥
Atmospheric pressure
(0.0kPa)
Correction set value: [
ST1
]' = [
ST1
] + [
ShIN
]
Correction set value: [
HYS1
]' = [
HYS1
] + [
ShIN
]
※
[
ShIN
] is the reference pressure set by Auto shift input.
Normal primary
pressure
Increase of primary
pressure
Drop of primary
pressure
Auto shift input
Time
Time
ON
OFF
OUT
Pressure
When Auto shift input signal remains at low level more than
1ms, the measured pressure at this point will be saved as
a reference value to make correct judgment regardless of
pressure changes. Corrected preset pressure value will be
applied after 7.5ms.
Measured reference pressure value will be saved in [
ShIN
]
▶
Example of Auto shift function
Key lock function
Zero-point adjustment function
High Peak / Low Peak Hold function
The key lock function prevents key operations so that
conditions set in each mode.
•
LOC1
: All keys are locked; therefore it is not available to
change parameter settings, preset value, zero adjustment,
High/Low peak check, and ShIN data initialization. (Lock
setting change is available)
•
LOC2
: Partially locked status; therefore it is not available
to change parameter settings only(Lock setting change is
available). Other settings are still available.
•
OFF
: All of the setting is available, all keys are unlocked. to
set detection sensitivity automatically at proper position.
The key lock function prevents key operations so that
conditions set in each mode.
The zero-point adjustment function forcibly sets the pressure
value to "zero" when the pressure port is opened to
atmospheric pressure. When the zero adjustment is applied,
analog output [Voltage or Current] is changed by this function.
(Press
+ keys over 1 sec. in RUN mode.)
This function is to diagnosis malfunction of the system
caused by parasitic pressure or to check through memorizing
the max./min. pressure occurred from the system.
ON
OFF
OUT
h
Time
Time
Pressure
Normal primary
pressure
Increase of primary
pressure
Drop of primary
pressure