EasyManuals Logo
Home>Autonics>Accessories>PSAN Series

Autonics PSAN Series User Manual

Autonics PSAN Series
13 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #2 background imageLoading...
Page #2 background image
E-5
(A)
Photo
electric
sensor
(B)
Fiber
optic
sensor
(C)
Door/Area
sensor
(D)
Proximity
sensor
(E)
Pressure
sensor
(F)
Rotary
encoder
(G)
Connector/
Socket
(H)
Temp.
controller
(I)
SSR/
Power
controller
(J)
Counter
(K)
Timer
(L)
Panel
meter
(M)
Tacho/
Speed/ Pulse
meter
(N)
Display
unit
(O)
Sensor
controller
(P)
Switching
power
supply
(Q)
Stepping
motor&
Driver&Controller
(R)
Graphic/
Logic
panel
(S)
Field
network
device
(T)
Software
(U)
Other
Pressure Sensor
to
from
Pa kPa MPa kgf/cm
2
mmHg mmHO psi bar inHg
1kPa 1000.000 1 0.001000 0.010197 7.500616 101.9716 0.145038 0.010000 0.2953
1kgf/cm
2
98066.54 98.066543 0.09806 1 735.5595 10000.20 14.22334 0.980665 28.95878
1mmHg 133.322368 0.133322 0.000133 0.001359 1 13.5954 0.019336 0.001333 0.039370
1mmH
O 9.80665 0.00980
-
0.000099 0.0735578 1 0.00142 0.000098 0.002895
1psi 6894.757 6.89757 0.00689 0.070307 51.71630 703.07 1 0.068947 2.036003
1bar 100000.0 100.0000 0.100000 1.019689 750.062 10196.89 14.50339 1 29.52998
1inHg 3386.417 3.388418 0.003386 0.034532 25.40022 345.31849 0.491158 0.033863 1
Pressure type
Gauge pressure
Negative pressure Standard pressure Compound pressure
Model
1
Voltage output PSAN-(L)V01C(P)V- PSAN-(L)01C(P)V- PSAN-(L)1C(P)V- PSAN-(L)C01C(P)V-
Current output PSAN-(L)V01C(P)A- PSAN-(L)01C(P)A- PSAN-(L)1C(P)A- PSAN-(L)C01C(P)A-
Hold/Auto shift input PSAN-(L)V01C(P)H- PSAN-(L)01C(P)H- PSAN-(L)1C(P)H- PSAN-(L)C01C(P)H-
Rated pressure range 0.0 to -101.3kPa 0.0 to 100.0kPa 0 to 1,000kPa -101.3kPa to 100.0kPa
Display pressure range 5.0 to -101.3kPa -5.0 to 110.0kPa -50 to 1,100kPa -101.3kPa to 110.0kPa
Min.display unit 0.1kPa 0.1kPa 1kPa 0.1kPa
Max. pressure range 2 times of rated pressure 2 times of rated pressure 1.5 times of rated pressure 2 times of rated pressure
Applied vapor • Pneumatic type
-
Air, Non-corrosive gas
Applied uid • Fluid type
-
Air, Non-corrosive gas and fluid that will not corrode SUS316L
Power supply 12V-24VDC ±10%(ripple P-P:Max. 10%)
Current consumption Max. 50mA(Analog Current Output type Max 75mA)
Control output
NPN or PNP open collector output
• Load voltage: Max. 30VDC • Load current: Max. 100mA • Residual voltage
-
NPN: Max. 1V, PNP: Max. 2V
Hysteresis
2
Min. display range
Repeat error ±0.2%F.S. ± Min. display range
Response time
Selectable 2.5ms, 5ms, 100ms, 500ms, 1000ms
Short circuit protection Built-in
Analog
output
3
Voltage output
• Output voltage: 1-5VDC ±2% F.S. • Linear: Within ±1% F.S. • Output impedance: 1kΩ
• Zero point: Max. 1VDC ±2% F.S. • Span: Max. 4VDC ±2% F.S. •
Response time
: 50ms
• Resolution: Automatically changed to 1/1000 or 1/2000 by pressure unit
Current output
• Output current: DC4-20mA ±2% • Linear: Max. ±1% F.S. • Zero-point: Max. DC4mA ±2% F.S.
• Span: Max. DC16mA ±2% F.S. •
Response time
:70ms
• Resolution: Automatically changed to 1/1000 or 1/2000 by pressure unit
Display method 7segment LED Display
Min. Display interval
4
Resolution
Pressure unit
1000 2000 1000 2000 1000 2000 1000 2000
MPa
--
0.001
-
0.001
---
kPa 0.1
-
0.1
-
1
--
0.1
kgf/cm
2
0.001
-
0.001
-
0.01
--
0.001
bar 0.001
-
0.001
-
0.01
--
0.001
psi
-
0.01
-
0.01
-
0.1
-
0.02
mmHg
-
0.4
-
0.8
inHg
-
0.02
-
0.03
mmHO 0.1
--
0.1
Display accuracy 0 to 50 : Max. ±0.5% F.S., -10 to 0℃ : Max. ±1% F.S.
Dielectric strength 1000VAC 50/60Hz for 1 minute
Insulation resistance Min. 50MΩ(at 500VDC megger)
Vibration 1.5mm amplitude at frequency of 10 to 55Hz(for 1 min.) in each of X, Y, Z direction for 2 hours
Environ-
ment
Ambient temperature
-10 to 50
, storage : -20 to 60
Ambient humidity
30 to 80%RH, storage :30 to 80%RH
Protection IP40(IEC specification)
Material
• Pneumatic type - Front case: PC, Rear case: PC, Pressure port: Nickel Plated Brass
• Fluid type - Front case: PC, Rear case: PA6, Pressure port: SUS316L
Cable
Connector cable (ø4, 5-wire, Length: 2m)
(AWG 24, Core diameter : 0.08mm, Number of cores : 40, Insulator out diameter: ø1mm)
Approval
Unit weight • Pneumatic type - Approx. 80g • Fluid type - Approx. 87.5g
Ex) For calculating 760mmHg as kPa : According to above chart, 1mmHg is 0.133322kPa, therefore 760mmHg will be 760×0.133322kPa=101.32472kPa.
1: For '(L)', '(P)', '
' of model name, refer to '
Ordering information'.
2: In hysteresis output mode, detection difference is variable.
3: It is allowed to select one analog output type only.
4: Resolution(1000/2000) of min. Display interval is automatically selected depend on pressure units.
F.S. : Rated pressure.
There may be ±1digit error in hysteresis by pressure unit calculation error.
Environment resistance is rated at no freezing or condensation.
Pressure conversion chart
Specifications

Other manuals for Autonics PSAN Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Autonics PSAN Series and is the answer not in the manual?

Autonics PSAN Series Specifications

General IconGeneral
BrandAutonics
ModelPSAN Series
CategoryAccessories
LanguageEnglish

Related product manuals