E-12
PSAN Series
※
If there is no additional key operation within 60 sec while setting, it
is returned to Run mode (Except for force output mode). Previously
set values are remained.
※
In case of changing output operation mode, no preset values will be
initialized. Instead, previous output operation settings will become
the preset values.
※
When using the forced output function, Hold/Auto shift function is
not available to use in Hold/Auto shift model.
※
When changing pressure display unit, resolution, and Hold Auto
shift input function, preset values will be initialized as shown the
next table. (When changing pressure display unit, preset value will
be automatically switched to changed pressure unit.)
● Factory default
(unit: kPa)
Hysteresis mode [
fOUT
]
If forced output control mode
is selected, pressure value is
displayed only.
(No output will be provided.)
Present pressure value and
will flash in turn every 0.5 sec.
Press
Key
Press
Key
Control output 1 OFF Control output 1 OFF
Control output 2 OFF Control output 2 OFF
※
1: Displayed only when
D-IN
is set to
SHFT
(PSAN-
H- models only)
※
If there is no Auto shift input, "
0
" will be displayed.(Refer to E-14 page for more details.)
High peak/Low peak function and Auto shift reference pressure check/change
"
HHHH
" will flash if retained
maximum pressure value
is above the upper limit of
rated pressure.
(For negative pressure type,
"
LLLL
" will flash)
"
LLLL
" will flash if retained
minimum pressure value
exceeds low-limit of rated
pressure.
For negative pressure type,
"
HHHH
" will flash)
Press
or key
to select set value
Press
+
keys over 1sec.
Press
+ keys over 1sec.
Press
+
keys over 1sec.
Remove the
retained minimum
pressure value.
Remove the
retained minimum
pressure value.
Retained maximum
pressure value will
flash every 0.5 sec.
Retained minimum
pressure value will
flash every 0.5 sec.
Auto shift reference
pressure value will
flash every 0.5 sec.
It will be returned to RUN
mode after previously
set Auto shift reference
pressure is removed.
Press
Key
for 3 sec.
Press
Key
for 3 sec.
Press
Key
Press
Key
Press Key for
3 sec in RUN mode.
※
1
Output
mode
Negative
pressure
0.0~-101.3
Standard
pressure
0.0~100.0
Standard
pressure
0~1,000
Compound
pressure
-101.3~100.0
HYS.M
ST1
:-50.0
HYS1
:0.0
ST2
:-50.0
HYS2
:0.0
ST1
:50.0
HYS1
:0.0
ST2
:50.0
HYS2
:0.0
ST1
:500
HYS
1:0
ST2
:500
HYS2
:0
ST1
:50.0
HYS1
:-50.0
ST2
:50.0
HYS2
:-50.0
WIN
LO-1
:0.0
HI-1
:-50.0
LO-2
:0.0
HI-2
:-50.0
LO-
1:0.0
HI-1
:50.0
LO-2
:0.0
HI-2
:50.0
LO-1
:0
HI-1
:500
LO-2
:0
HI-2
:500
LO-1
:-50.0
HI-1
:50.0
LO-2
:-50.0
HI-2
:50.0
HY-W
ST1
:-50.0
HYS1
:0.0
LOW
:0.0
HIGH
:-50.0
ST1
:50.0
HYS
1:0.0
LOW
:0.0
HIGH
:50.0
ST1
:500
HYS
1:0
LOW
:0
HIGH
:500
ST1
:50.0
HYS1
:-50.0
LOW
:-50.0
HIGH
:50.0
AUTO
ST1
:0.0
ST2
:-50.0
SET
:-25.0
ST1
:0.0
ST2
:50.0
SET
:25.0
ST1
:0
ST2
:500
SET
:250
ST1
:-50.0
ST2
:50.0
SET
:0.0