Check the water supply device and the release often. You should avoid the
condition of no water or air entering into system, as this will inuence
unit‘s performance and reliability. You should clear the pool/spa lter reg-
ularly to avoid damage to the unit as a result of the dirty of clogged lter.
The area around the unit should be dry, clean and well ventilated. Clean
the side heating exchanger regularly to maintain good heat exchange as
conserve energy .
The operation pressure of the refrigerant system should only be serviced
by a certied technician .
Check the power supply and cable connection often. Should the unit begin
to operate abnormally, switch it o and contact the qualied technician.
Discharge all water in the water pump and water system, so that freezing
of the water in the pump or water system does not occur. You should dis-
charge the water at the bottom of water pump if the unit will not be used
for an extended period of time. You should check the unit thoroughly and
ll the system with water fully before using it for the rst time after a
prolonged period of no usage.
Checks to the area
Prior to beginning work on systems containing ammable refrigerants,
safety checks are necessary to ensure that the risk of ignition is mini-
mised. For repair to the refrigerating system, the following precautions
shall be complied with prior to conducting work on the system.
Work procedure
Work shall be undertaken under a controlled procedure so as to minimise
the risk of a ammable gas or vapour being present while the work is be-
ing performed.
General work area
All maintenance sta and others working in the local area shall be in-
structed on the nature of work being carried out. Work in conned spaces
shall be avoided. The area around the workspace shall be sectioned o.
Ensure that the conditions within the area have been made safe by control
of ammable material.
Checking for presence of refrigerant
The area shall be checked with an appropriate refrigerant detector prior
to and during work, to ensure the technician is aware of potentially am-
mable atmospheres. Ensure that the leak detection equipment being used
is suitable for use with ammable refrigerants, i.e. non-sparking, ade-
quately sealed or intrinsically safe.
Presence of re extinguisher
If any hot work is to be conducted on the refrigeration equipment or any
associated parts, appropriate re extinguishing equipment shall be avail-
5. MAINTENANCE AND INSPECTION