5
Overview of functions
1)
Operates only when a safety edge is used
Function MLS Basic Card MLS Professional Card
Setting mode (up/down in dead-man mode) X X
Automatic ascent (UP) X X
Automatic descent (DOWN) X
1)
Anti-pull-in cable safety X X
Slack rope switch debounced X X
Button input: UP/STOP/DOWN/STOP X
Automatic closing X
Partial opening X
Pneumatic safety edge X
Electrical safety edge X
Safety edge switchover: 1.2 kOhm/8.2 kOhm X
Optoelectronic safety edge: FRABA OSE X
Photoelectric barrier X
Yard light X
Trafc lights/door status indicator X X
Warning lamp X
Power supply lamp X X
LED UP X X
LED DOWN X X
LED Operating status X
LED ERROR Code X
LED Safety edge X
LED Pre-limit switch X
Voltage output (24 V DC / 200 mA) X X