12 Bend-Tech Dragon A150
Plasma Cutting Guide
Consumables
01
Consumables Parts List
Inspecting and Changing Consumables
Nozzle
Electrode
The Operator can determine electrode life by measuring pit depth. Pit depth is the distance
from the surface of the copper electrode piece to the halfnium located at the center of the
Check for dross build up
both inside and outside
Check to see if
of round.
45 Amp Consumables 65 Amp Consumables 85 Amp Consumables
Components Standard Fine Cut Components Standard Fine Cut Components Standard Fine Cut
220941 220930 220819 220930 220816 220930
Electrode 220842 220842 Electrode 220842 220842 Electrode 220842 220842
Shield 220817 220948 Shield 220817 220948 Shield 220817 220948
Swirl Ring 220857 220857 Swirl Ring 220857 220857 Swirl Ring 220857 220857
Retaining
Cap
220854 220854
Retaining
Cap
220854 220854
Retaining
Cap
220854 220854