EasyManuals Logo
Home>Bosch>Service Equipment>ACS 511

Bosch ACS 511 User Manual

Bosch ACS 511
40 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #11 background imageLoading...
Page #11 background image
1 689 975 252 2019-05-15| Robert Bosch GmbH
Service phases | ACS 511 | 11 en
8. Service phases
i This section describes all of the ACS 511 service
phases. In addition, it explains the hydraulic and
electric circuits by presenting the hydraulic diagram
and providing a brief description of the components
involved in each function.
8.1 Recovery
i In this service phase, the refrigerant is extracted
from the vehicle air conditioning system.
1. The ACS 511 is connected to the vehicle with the
service hoses T1 and T2.
2. Open the service quick-release coupling valves.
The pressure on the high and low pressure side of
the vehicle air conditioning system is indicated on
the pressure gages M1 and M2.
i Opening the HP and LP valves on the ACS 511
causes the refrigerant to flow to the solenoid valves
EV10 (open) and EV3 (closed).
i The pressure sensor P1 checks the pressure of the
vehicle air conditioning system (whether or not there
is refrigerant in the vehicle air conditioning system).
3. starts extraction of the refrigerant.
The solenoid valves EV10, EV3 and EV5 are
opened and the compressor (6) is started.
R The refrigerant flows through the solenoid valves
EV 10, EV3 and EV5, the mechanical filter (F1), the
expansion valve (3), and the condenser/separator (4).
R The expansion valve maintains a constant pressure
at the evaporator/oil separator (4).
R In the evaporator/oil separator (4), the oil extracted
from the vehicle air conditioning system is separated
from the refrigerant and routed into the used oil
bottle.
R The refrigerant then flows on through the combo fil-
ter (F2) and the compressor (6) into the condenser/
separator (5), and finally into the internal refrigerant
cylinder.
i The combo filter (F2) cleans the extracted refriger-
ant of suspended particles and moisture.
i In the evaporator/oil separator (5), the oil taken in
from the compressor is separated from the refriger-
ant and fed back to the compressor.
i If the pressure at sensor P1 falls below the value
saved in the software, the function stops automati-
cally, the program waits 5 minutes for a pressure
increase and, if necessary, restarts with a second
recovery cycle.
At the end of this phase, the solenoid valves EV10, EV3
and EV5 are closed and the compressor 6 is turned off.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bosch ACS 511 and is the answer not in the manual?

Bosch ACS 511 Specifications

General IconGeneral
BrandBosch
ModelACS 511
CategoryService Equipment
LanguageEnglish

Related product manuals