12. Maintenance
! Work on electrical equipment is only to be
performed by persons with sufficient knowledge
and experience of electrical systems!
12.1 Cleaning
! Do not use abrasive cleaning agents and coarse
workshop cloths!
The housing and the LCD are only to be cleaned
using a soft cloth and neutral cleaning agents.
12.2 Spare and wearing parts
Description Order number
Combo filter SP00100001
Vacuum pump oil SP00100086
Roll of paper for printer SP00100087
Service hose 2.5m (HP) SP00100029
Service hose 5m (HP) SP00100035
Service hose 2.5m (LP) SP00100030
Service hose 5m (LP) SP00100036
Quick-release coupling (HP) SP00100083
Quick-release coupling (LP) SP00100082
Used oil bottle SP00100113
Fresh oil bottle SP00100112
Adapter set 2.5 m - 5 m SP00100075
Adapter for connection to an external
refrigerant cylinder 1/4" SAE
SP00100019
Adapter for connection to an
external refrigerant cylinder
W21.8-14 x 1/4” FL (EU standard)
SP00100080
12.3 Maintenance interval
Description Period
Vacuum pump oil replacement and
system leak test
see display (30h)
Replacement of combo filter see display (150kg)
! Never perform any maintenance work which is not
expressly recommended in this Section.
! Contact customer service if components have to be
replaced other than in the course of maintenance
work.
12.4 Calibrating internal refrigerant
cylinder scales
i The internal refrigerant cylinder is calibrated at the
factory.
i Contact customer service for calibration of the
internal refrigerant cylinder.
12.5 Removing the fresh and used oil
bottles
! Do not exert excessive force when removing or
inserting the fresh oil and used oil bottles.
12.5.1 Removing the fresh oil bottle
1. Pull the quick release coupling downwards slightly
2. Pull the fresh oil bottle downwards.
2.
1.
Fig. 5: Removing the fresh oil bottle
12.5.2 Removing the used oil bottle
1. Pull the quick release coupling downwards slightly
2. Pull the used oil bottle downwards.
2.
1.
Fig. 6: Removing the used oil bottle

Table of Contents

Other manuals for Bosch ACS 810

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bosch ACS 810 and is the answer not in the manual?

Bosch ACS 810 Specifications

General IconGeneral
BrandBosch
ModelACS 810
CategoryService Equipment
LanguageEnglish

Related product manuals