Glossary | ACS 810 | 65 | en
1 689 989 601 2020-12-01| Robert Bosch GmbH
14. Glossary
R Expert Mode: Supporting messages are displayed
on the screen for each individual action step.
R Combo filter: Filter and dryer cartridge for
removing fine particles and moisture from the
refrigerant.
R PS2 stick:
Storage medium with PS2 connection; used in
order to perform software update of ACS 810, or to
store data from the internal memory of ACS 810 for
data management on a PC.
R Recovery phase:
The refrigerant is removed from the vehicle air
conditioner using suction, cleaned and routed into
the internal vessel of the ACS 810. The refrigerant
oil collected in the process is drained into the used
oil bottle at the ACS 810.
R Vacuum phase:
A vacuum is generated in the vehicle air
conditioning system. Measurement of the drop in
pressure commences as soon as the vacuum has
been generated.
R Fresh oil refill phase:
Fresh oil is added to the vehicle air conditioner.
R Filling phase:
A certain quantity of refrigerant is added to the
vehicle air conditioner.
15. Technical data
15.1 ACS 810
Property Value/range
Dimensions H x W x D 1270 x 690 x 660 mm
Weight 120 kg
Operating voltage 230 VAC ± 10 %
Frequency 50 Hz
Workplace emission sound pressure
level as per EN ISO 11204
< 70 dB(A)
Refrigerant R134a
Low-pressure gauge -1 bar – 16 bar ± 1 %
High-pressure gauge -1 bar – 40 bar ± 1%
Capacity of internal refrigerant cylinder 40 l
Safety class IP 20
Power output 1300 W
15.2 Ambient temperature
Property Value/range
Storage and transport -25 °C – 60 °C
-13 °F – 140 °F
Operation 10 °C – 45 °C
50 °F – 113 °F
15.3 Air humidity
Property Value/range
Storage and transport <75 %
Operation <90 %
15.4 Electromagnetic compatibility
This product complies with the standards EN 61000-3-
2 and EN61000-3-3.