Compress 3400iAWS E – 6721852787 (2023/01)
24
Ventilation
Op. mode
Time program
–Reset time prog.
Humidity
Air quality
–Bypass
Supply air temp. control
Reheat supp.air temp. (After-heater supply air temperature)
–Filter timer
Confirm filter change
Rename ventil. zone
Pool
Switch on pool heating
Pool temperature
Allow add. heater for pool
Holiday
Smart grid
–Heating
Selectable peak
Forced peak
–DHW
Selectable peak
PV system
–Heating peak
–DHW peak
Cooling setback mode
Energy manager
–Heating peak
Only cool with EM
Settings
–Language
–Time format
–Time of Day
Date format
Date [DD.MM]
–Auto. time switchover
Display contrast
Warning sound blocked
Warning sound blocked
Warn. sound blocked by
Warn. snd. blocked until
–Reduced DHW temp.
DHW temp. correction
Time correction
Standard display
Internet password
Internet
–Establish connection
Terminate connection
Low-noise operation
–Low-noise operation
Low-noise operation of
Low-noise operation until
Min. outside temp.
–Reset
–Reset settings
10 Overview Info
This is an overview of all possible information. In each installation only
information of installed modules or components are shown.
Heating or Heating/Cooling
–Heating/cooling mode
Set room temp. (set room temperature)
Measured room temp. (measured room temperature)
Measured flow temp. (measured flow temperature)
DHW
Set temp. (set DHW temperature)
Measured temp. (measured DHW temperature)
DHW (Fresh water station)
Ventilation
Op. mode
Outside temperature
–Supply air temp.
–Ex.air temp.
Exhaust air temp.
Reheat supp.air temp. (Reheater supply air temperature)
–Ex.air humid.
Ex.air quality
Humidity remote ctrl
Amb. air humid.
Amb. air quality
–Bypass
Rem. filter elapsed time
Pool
Set pool temperature
Current pool temperature
Operating data
Control operating hours
Aux. heater energy cons.
Op. hours for comp. heat.
Op. hours for comp. cool.
Op. hours for comp. DHW
Op. hours for comp. pool
Number of heating starts
Number of cooling starts
–Number of DHW starts
Number of pool starts
Energy consump.
–Total

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bosch Compress 3400iAWS E and is the answer not in the manual?

Bosch Compress 3400iAWS E Specifications

General IconGeneral
BrandBosch
ModelCompress 3400iAWS E
CategoryHeat Pump
LanguageEnglish

Related product manuals