Page #13 background image
Electrical Connection | 6
Instruction Manual R5 RA 0063 F5K_EN_en 13 | 32
6 Electrical Connection
DANGER
Live wires.
Risk of electrical shock.
Electrical installation work must only be executed by qualified personnel.
CURRENT PROTECTION OF THE CUSTOMER INSTALLATION:
DANGER
Missing current protection.
Risk of electrical shock.
Current protection according to EN 60204-1 must be insured by the customer on its installation.
The electrical installation must comply with the applicable national and international standards.
NOTICE
Electromagnetic compatibility.
Make sure that the motor of the machine will not be affected by electric or electro- magnetic dis-
turbance from the mains, if necessary seek advice from Busch.
Make sure that the EMC of the machine is compliant with the requirements of your supply net-
work system, if necessary provide further interference suppression (EMC of the machine, see EU
Declaration of Conformity [30] or UK Declaration of Conformity [31]).
6.1 Machine delivered without Control Box or Variable
Speed Drive (VSD)
DANGER
Live wires.
Risk of electrical shock.
Electrical installation work must only be executed by qualified personnel.
Make sure that the power supply for the motor is compatible with the data on the nameplate of
the motor.
If the machine is equipped with a power connector, install a residual current protective device to
protect persons in case of isolation default.
Busch recommends installing a type B residual protective device suitable for the electrical in-
stallation.
Provide a lockable disconnect switch or an emergency stop switch on the power line so that the
machine is completely secured in case of an emergency situation.