10 | Decommissioning
24 | 32 Instruction Manual R5 RA 0063 F5K_EN_en
10 Decommissioning
DANGER
Live wires.
Risk of electrical shock.
● Electrical installation work must only be executed by qualified personnel.
CAUTION
Hot surface.
Risk of burns!
● Prior to any action requiring touching the machine, let the machine cool down first.
● Shut down the machine and lock against inadvertent start up.
● Disconnect the power supply.
● Vent the connected lines to atmospheric pressure.
● Disconnect all connections.
If the machine is going to be stored:
● See Storage [➔9].
10.1 Dismantling and Disposal
● Drain and collect the oil.
● Make sure that no oil drips onto the floor.
● Remove the exhaust filters.
● Remove the oil filter.
● Separate special waste from the machine.
● Dispose of special waste in compliance with applicable regulations.
● Dispose of the machine as scrap metal.