13 | Technical Data
28 | 32 Instruction Manual R5 RA 0063 F5K_EN_en
13 Technical Data
RA 0063 F 5K
Nominal pumping speed (50Hz / 60Hz) m³/h 63 / 76
Ultimate pressure (without gas ballast valve) hPa (mbar)
abs.
0.1 … 0.5 ► see nameplate (NP)
Ultimate pressure (with gas ballast valve) hPa (mbar)
abs.
0.5 … 1.5
Nominal motor speed (50Hz / 60Hz) min
-1
1500 / 1800
Nominal motor rating (50Hz / 60Hz) kW 2.0 / 2.4
Power consumption at 100 mbar (50Hz / 60Hz) kW 1.3 / 1.5
Power consumption at ultimate pressure
(50Hz / 60Hz)
kW 0.7 / 0.8
Noise level (ENISO2151) (50Hz / 60Hz) dB(A) 64 / 67
Water vapor tolerance max. (with gas ballast
valve)
hPa (mbar)
abs.
40
Water vapor capacity (with gas ballast valve) kg / h 1.8
Operating temperature (50Hz / 60Hz) °C 84 / 92
Ambient temperature range °C 5 ... 40
Ambient pressure Atmospheric pressure
Oil capacity l 1.0
Weight approx. kg 52