Page 5 - Manual FA01383-EN - 04/2021 - © CAME S.p.A. - The contents of this manual may be changed at any time and without notice. - Translation of the original instructions
PRODUCT DATA AND INFORMATION
Key
This symbol shows which parts to read carefully.
This symbol shows which parts describe safety issues.
This symbol shows what to tell users.
The measurements, unless otherwise stated, are in millimetres.
Description
803BB-0160
GGT40AGS - Automatic barrier with gearmotor 24 V DC with encoder; painted galvanised steel cabinet; accessories available. Balance spring included.
803BB-0200
GGT40RGS - Automatic barrier with irreversible gearmotor 24 V DC with encoder; painted galvanised steel cabinet; accessories available. Balance spring included.
803BB-0300
GGT40RX4 - Automatic barrier with irreversible gearmotor 24 V DC with encoder; satin-finish AISI 304 steel cabinet; accessories available. Balance spring included.
803BB-0240
GGT40AX4 - Automatic barrier with gearmotor 24 V DC with encoder; satin-finish AISI 304 steel cabinet; accessories available. Balance spring included.
803BB-0260
GGT40AX6 - Automatic barrier with irreversible gearmotor 24 V DC with encoder; satin-finish AISI 316 steel cabinet; accessories available. Balance spring included.
803BB-0280
GGT40ACS - Automatic barrier with gearmotor 24 V DC with encoder; custom-RAL painted galvanised steel cabinet; accessories available. Balance spring included.
Intended use
The ideal solution for access roads with heavy transit flows
Any installation and/or use other than that specified in this manual is forbidden.
Usage limitations
MODELS GGT40AGS GGT40RGS GGT40RX4 GGT40AX4 GGT40AX6 GGT40ACS
Max. net clearance width (m) 4 4 4 4 4 4
Technical data
MODELS GGT40AGS GGT40RGS GGT40RX4 GGT40AX4 GGT40AX6 GGT40ACS
Power supply (V - 50/60 Hz) 230 AC 120 AC 120 AC 230 AC 230 AC 230 AC
Maximum current draw (mA) 1,1 2,2 2,2 1,1 1,1 1,1
Motor power supply (V) 24 DC 24 DC 24 DC 24 DC 24 DC 24 DC
Standby consumption (W) 7 7 7 7 7 7
Power (W) 240 240 240 240 240 240
Colour 7024 7024 - - - RAL X
Operating temperature (°C) -20 ÷ +55
(-40 with item
001PSRT01)
-20 ÷ +55
(-40 with item
001PSRT01)
-20 ÷ +55
(-40 with item
001PSRT01)
-20 ÷ +55
(-40 with item
001PSRT01)
-20 ÷ +55
(-40 with item
001PSRT01)
-20 ÷ +55
(-40 with item
001PSRT01)
Torque (Nm) 300 300 300 300 300 300
Opening time at 90° (s) 2 ÷ 6 2 ÷ 6 2 ÷ 6 2 ÷ 6 2 ÷ 6 2 ÷ 6
Cycles/hour 350 350 350 350 350 350
Cycles/day 5400 5400 5400 5400 5400 5400
Protection rating (IP) 54 54 54 54 54 54
Insulation class I I I I I I
Weight (kg) 56 56 56 56 56 56
Fuse table
MODELS GGT40AGS GGT40RGS GGT40RX4 GGT40AX4 GGT40AX6 GGT40ACS GGX40AGS
Line fuse 1.6 A-F 3.15 A-F 3.15 A-F 1.6 A-F 1.6 A-F 1.6 A-F 1.6 A-F
Accessory fuse 2 A-F 2 A-F 2 A-F 2 A-F 2 A-F 2 A-F 2 A-F
Control board fuse 4 A-F 4 A-F 4 A-F 4 A-F 4 A-F 4 A-F 4 A-F
Motor fuse 10 A-F 10 A-F 10 A-F 10 A-F 10 A-F 10 A-F 10 A-F