STANDARD FEATURES AND ACCESSORIES
Table 1—Standard Features
Ease Of Installation
Indoor and Outdoor Compact Size S
Outdoor Unit Wall Mounting Kit A
Outdoor Unit Stacking Kit A
Indoor Mounting Bracket S
Comfort Features
Microprocessor Controls S
Wireless Remote Control S
Automatic Air Sweep S
Air Direction Control S
Auto Restart Function S
Cold Blow Protection On Heat Pumps S
Turbo Mode S
Silence Mode S
Follow Me S
Energy Saving Features
Sleep Mo de S
Stop/Start Timer S
46 ° F Heating Mode (Heating Setback) S
Safety And Reliability
3 Minute Time Delay For Compressor S
Over Current Protection For Compressor S
Crankcase Heater (stand ar d on sizes 30 and 36 Heat Pump) A
Indoor Coil Freeze Protection S
Indoor Coil High Temperature Protection On Heat Pumps S
Condenser High Temperature Protection On Heat Pumps S
Accumu lator On Heat Pumps S
Ease Of Service And Maintenance
Cleanable Filters S
Diagnostics S
Liquid Line Pressure Taps S
Suction And Discharge Pressure Taps S
Application Flexibility
Low Ambient Controls ( --20_F) (--28.9_C) A
3--Phase on size 34 S
Wind Baffles A
Condensate Pumps S
Wired Controls A
Legend
SStandard
A Accessory
ACCESSORIES
Table 2—Accessories
Ordering No. Description For Models
KSACN0101AAA Wired Remote Control All Sizes
40MK--B01C----3 Grille/Ceiling panel Cassette Indoor units
KSALA0801AAA
Low Ambient Control (for
cooling --20F)
24AHA4/25HHA4
(208/230V)
KSALA0901AAA
Low Ambient Control (for
cooling --20F)
24AHA4 (460V--3)
KAACH1401AAA Crankcase Heater
24AHA4 Sizes 18--36
(208/230V)
KAACH1501AAA Crankcase Heater 24AHA4 Size 36 (460V--3)
KAACH1701AAA Crankcase Heater 25HHA4 Size 24 (208/230V)
KAAWS0101AAA
Winter Start Kit (for low
ambient on cooling only
systems)
24AHA4 All Sizes
KHAIR0201AAA
Isolation Relay (Required
when using Low Ambient
cooling with HP)
25HHA4 All Sizes
KSAHS1501AAA
Hard Start Kit (Capacitor &
Relay)
24AHA4/25HHA4
(208/230V--1)
53DS--900-- ----087 Wind Baffle
24AHA4 Sizes 18 & 24;
25HHA4 Size 24
53DS--900-- ----071 Wind Baffle
24AHA4/25HHA4 Sizes 30
&36
53DS--900-- ----075 Stackin g Kit 24AHA4 Sizes 18, 24
53DS--900-- ----076 Stackin g Kit 24AHA4 Sizes 30, 36
53DS--900-- ----077 Wall Mount Kit
24AHA4 Sizes 18, 24 and
25HHA4 Size 24
53DS--900-- ----078 Wall Mount Kit
24AHA4/25HHA4 Sizes 30,
36
KAALS0201LLS
Liquid Line Solenoid for
Cooling Only
24AHA4 All Sizes --
Required for Long Line
Applications
KHALS0401LLS
Liquid Line Solenoid for
Heat Pump
25HHA4 All Sizes --
Required for Long Line
Applications
INDOOR UNIT ACCESSORIES
Grille
To maximize shipping efficiency , the grille for the in--ceiling
cassette is set up as an accessory.
NOTE: Grille is required.
Wired Remote Controller
For applications where the use of wireless remote control is not
desired, the MK units can be controlled by means of a wired
wall-- mounted control with an LCD display.
Fig. 1 – Wall Mounted Control with LCD Display