SPECIFICATIONS OUTDOOR
Table 2—Outdoor
HEAT PUMP
System
Size 36 48
Outdoor Model 38MBRQ36A-- 3 38MBRQ48A-- 3
Electrical
Voltage, Phase, Cycle V/Ph/Hz 208/230-1-60 208/230-1-60
MCA A. 30 35
MOCP - Fuse Rating A. 50 50
Operating Range
Cooling Outdoor DB Min - Max °F (°C) -4~ 122 (-20~ 50) -4~ 122 (-20~ 50)
Heating Outdoor DB Min - Max °F (°C) -22~ 86 (-30~ 30) -22~ 86 (-30~ 30)
Piping
Total Piping Length ft (m) 213 (65) 213 (65)
Piping Lift
*
ft (m) 98 (30) 98 (30)
Pipe Connection Size - Liquid in (mm) 3/8 (9.52) 3/8 (9.52)
Pipe Connection Size - Suction in (mm) 5/8 (16) 5/8 (16)
Refrigerant
Type R410A R410A
Charge lbs (kg) 6.72 (3.05) 9.26 (4.2)
Metering Device EEV EEV
Outdoor Coil
Face Area Sq. Ft. 8.0 13.6
No. Rows 2 2
Fins per inch 18 18
Circuits 4 8
Compressor
Type Rotary Inverter Rotary Inverter
Model ATF310D43UMT ATQ420D1UMU
Oil Type ESTER OIL VG74 ESTER OIL VG74
Oil Charge Fl. Oz. 28.2 39.5
Rated Current RLA 8.9 11.9
Outdoor
Unit Width in (mm) 40.63 (1032) 40.63 (1032)
Unit Height in (mm) 31.89 (810) 52.48 (1333)
Unit Depth in (mm) 17.91 (544) 17.64 (448)
Net Weight lbs (kg) 136.47 (61.9) 217.4 (98.6)
Airflow CFM 2,130 4,500
Sound Pressure dB(A) 63.0 62.5
* Condensing unit above or below indoor unit