EasyManuals Logo
Home>Carrier>Air Conditioner>40MVC

Carrier 40MVC User Manual

Carrier 40MVC
34 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #10 background imageLoading...
Page #10 background image
10
PERFORMANCE DATA
COOLING CAPACITIES
38MVC(Q)009--1 / 40MVC(Q)009--1
Te m p _F(_C)
Air Entering
Condenser
(Edb)
A i r E n t e r i n g E v a p o r a t o r --- C f m / B F
190/0.04 259/0.04 327/0.05
Air Entering Evaporator --- Ewb _F(_C)
57
(13.89)
62
(16.67)
67
(19.44)
72
(22.22)
57
(13.89)
62
(16.67)
67
(19.44)
72
(22.22)
57
(13.89)
62
(16.67)
67
(19.44)
72
(22.22)
55
(12.78)
TCG 7.70 8.60 9.37 10.14 9.08 9.34 10.07 10.66 9.75 9.74 10.44 10.93
SHG 7.44 6.61 5.80 4.95 9.08 7.59 6.45 5.29 9.75 8.30 6.95 5.50
TC 7.69 8.58 9.36 10.12 9.07 9.32 10.06 10.65 9.74 9.72 10.42 10.92
kW 0.48 0.48 0.48 0.47 0.48 0.48 0.47 0.47 0.48 0.48 0.47 0.47
CMP 0.39 0.39 0.39 0.38 0.39 0.39 0.38 0.38 0.39 0.39 0.38 0.38
LDB 45.0 48.9 52.8 56.9 48.4 53.5 57.6 61.7 52.9 56.9 60.7 64.8
LWB 40.9 45.6 50.8 56.2 43.3 49.2 54.5 60.2 45.4 51.6 56.9 62.6
65
(18.33)
TCG 7.40 8.31 9.14 9.95 8.88 9.08 9.87 10.51 9.53 9.50 10.27 10.81
SHG 7.40 6.57 5.71 4.88 8.88 7.55 6.41 5.25 9.53 8.34 6.98 5.51
TC 7.38 8.29 9.13 9.93 8.86 9.07 9.85 10.50 9.52 9.48 10.26 10.80
kW 0.54 0.55 0.55 0.54 0.55 0.55 0.54 0.54 0.55 0.55 0.54 0.54
CMP 0.45 0.45 0.46 0.45 0.46 0.46 0.45 0.45 0.45 0.45 0.45 0.45
LDB 45.1 49.1 53.2 57.2 49.1 53.6 57.7 61.9 53.5 56.7 60.6 64.8
LWB 41.6 46.2 51.2 56.5 43.6 49.6 54.8 60.3 45.7 51.9 57.1 62.7
75
(23.89)
TCG 7.50 7.94 8.88 9.73 8.56 8.72 9.57 10.33 9.28 9.12 10.00 10.61
SHG 7.50 6.52 5.62 4.80 8.56 7.49 6.33 5.21 9.28 8.24 6.93 5.50
TC 7.49 7.93 8.87 9.71 8.54 8.70 9.55 10.31 9.26 9.10 9.98 10.60
kW 0.61 0.61 0.62 0.62 0.62 0.62 0.62 0.62 0.62 0.62 0.62 0.62
CMP 0.52 0.52 0.53 0.52 0.52 0.53 0.53 0.52 0.53 0.53 0.52 0.52
LDB 44.7 49.2 53.6 57.6 50.1 53.8 57.9 62.0 54.2 57.0 60.7 64.8
LWB 41.4 47.0 51.7 56.9 44.1 50.1 55.2 60.6 46.0 52.3 57.4 62.8
85
(29.44)
TCG 7.20 7.55 8.50 9.42 8.20 8.09 9.25 10.04 8.99 8.72 9.62 10.34
SHG 7.20 6.49 5.52 4.67 8.20 7.34 6.28 5.12 8.99 8.23 6.86 5.44
TC 7.18 7.53 8.48 9.41 8.19 8.07 9.23 10.03 8.97 8.71 9.61 10.33
kW 0.68 0.69 0.69 0.70 0.69 0.69 0.70 0.70 0.70 0.70 0.70 0.70
CMP 0.59 0.59 0.60 0.60 0.60 0.60 0.60 0.60 0.60 0.60 0.60 0.60
LDB 46.0 49.3 54.0 58.2 51.3 54.3 58.1 62.3 54.9 57.0 60.9 65.0
LWB 42.1 47.8 52.5 57.5 44.7 51.1 55.6 60.9 46.4 52.7 57.8 63.1
95
(35)
TCG 6.86 7.02 8.06 9.06 7.82 7.63 8.86 9.66 8.57 8.22 9.22 9.98
SHG 6.86 6.37 5.42 4.53 7.82 7.28 6.20 5.00 8.57 8.22 6.83 5.35
TC 6.85 7.00 8.05 9.05 7.80 7.61 8.85 9.64 8.55 8.20 9.21 9.97
kW 0.76 0.76 0.77 0.78 0.77 0.77 0.78 0.78 0.78 0.78 0.78 0.78
CMP 0.66 0.67 0.68 0.69 0.67 0.67 0.68 0.69 0.68 0.68 0.69 0.69
LDB 47.5 49.8 54.4 58.8 52.6 54.4 58.3 62.7 56.0 57.0 60.9 65.2
LWB 42.8 48.9 53.3 58.1 45.3 51.7 56.2 61.4 46.9 53.3 58.2 63.4
105
(40.56)
TCG 6.40 6.54 7.59 8.70 7.39 7.09 8.26 9.20 8.10 8.10 8.73 9.56
SHG 6.40 6.19 5.28 4.40 7.39 7.09 6.11 4.86 8.10 8.10 6.74 5.26
TC 6.39 6.53 7.58 8.69 7.38 7.07 8.25 9.19 8.08 8.09 8.72 9.54
kW 0.84 0.85 0.86 0.87 0.86 0.85 0.87 0.87 0.86 0.86 0.87 0.87
CMP 0.75 0.75 0.76 0.77 0.76 0.76 0.77 0.77 0.77 0.77 0.77 0.78
LDB 49.6 50.6 55.0 59.4 54.0 55.0 58.6 63.1 57.3 57.3 61.2 65.4
LWB 43.9 49.9 54.2 58.7 46.0 52.5 57.0 61.9 47.5 53.4 58.7 63.8
115
(46.11)
TCG 5.87 5.81 7.03 8.09 6.91 6.91 7.64 8.67 7.59 7.59 8.01 8.99
SHG 5.87 5.79 5.08 4.18 6.91 6.91 5.97 4.70 7.59 7.59 6.61 5.10
TC 5.85 5.80 7.01 8.08 6.89 6.90 7.63 8.65 7.57 7.57 7.99 8.97
kW 0.93 0.93 0.95 0.96 0.95 0.95 0.96 0.97 0.96 0.96 0.96 0.97
CMP 0.83 0.83 0.85 0.86 0.85 0.85 0.86 0.87 0.86 0.86 0.86 0.87
LDB 52.0 52.4 55.9 60.3 55.6 55.6 59.0 63.6 58.7 58.7 61.5 65.8
LWB 45.0 51.3 55.2 59.7 46.7 52.8 57.8 62.5 48.1 54.0 59.4 64.3
125
(51.67)
TCG 5.33 5.33 6.22 7.44 6.37 6.37 6.80 8.09 7.03 7.03 7.00 8.35
SHG 5.33 5.33 4.75 3.96 6.37 6.37 5.71 4.54 7.03 7.03 6.31 4.96
TC 5.31 5.31 6.21 7.42 6.35 6.35 6.78 8.07 7.02 7.02 6.99 8.33
kW 1.03 1.03 1.04 1.06 1.04 1.04 1.05 1.07 1.05 1.05 1.05 1.07
CMP 0.93 0.93 0.94 0.96 0.94 0.94 0.95 0.97 0.95 0.95 0.95 0.97
LDB 54.4 54.5 57.3 61.3 57.5 57.5 59.8 64.1 60.2 60.2 62.2 66.2
LWB 46.2 52.3 56.7 60.8 47.6 53.5 58.8 63.2 48.8 54.6 60.4 64.9
LEGEND
BF --- Bypass Factor
CMP --- Compressor
Edb --- Entering Dry Bulb
Ewb --- Entering Wet Bulb
k W --- To t a l Po w e r
LDB --- Leaving D ry Bulb
L W B --- L e a v i n g We t B u l b
SHG --- Gross Sensible Capacity (1000 Btu/hour)
TC --- Total Net Cooling Capacity (1000 Btu/hour)
TCG
---
Gross
Cooling
Capacity
(1000
Btu/hour)
NOTES:
1. Direct interpolation is permissible. Do not extrapolate.
2. The SHG is based on 80_F (26.67_C) edb temperature of air
entering indoor coil.
Below 80_F (26.67_C) edb, subtract (corr factor x cfm) from
SHG.
Above 80_F (26.67_C) edb, add (corr factor x cfm) to SHG.
Correction Factor = 1.10 x (1 --- BF) x (edb --- 80).
38/40MVC, MVQ

Other manuals for Carrier 40MVC

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Carrier 40MVC and is the answer not in the manual?

Carrier 40MVC Specifications

General IconGeneral
BrandCarrier
Model40MVC
CategoryAir Conditioner
LanguageEnglish

Related product manuals