Cisco Aironet Series Power Injectors AIR-PWRINJ-60RGD1= and AIR-PWRINJ-60RGD2= Installation Instructions
Unpacking the Power Injector
Unpacking the Power Injector
The following items are shipped with the power injector:
• A power injector with an AC line cord attached
• Two RJ45 male plug waterproof connectors (Figure 3)
• Ground cable (Figure 3)
If any item is missing or damaged, contact your Cisco representative or reseller.
Warning
To reduce the risk of fire, use only No. 26 AWG or larger telecommunication line cord.
Statement 1023
Note You must use shielded outdoor rated Ethernet cables with this device.
Note The power injector is not suitable for operation in a building’s environmental air space and should not
be installed in these environments.
Note Ethernet cable from the switch to the power injector must be a shielded CAT5e or higher Ethernet cable.
The Ethernet cable from the power injector to the access point must be a shielded outdoor-rated CAT5e
or higher Ethernet cable with a 0.20 to 0.35 inch diameter.
Figure 3 Factory-Shipped RJ45 Waterproof Connectors and Ground Cable