EasyManuals Logo
Home>Cisco>Network Router>ASR 1002

Cisco ASR 1002 User Manual

Cisco ASR 1002
72 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #55 background imageLoading...
Page #55 background image
Page 55 of 72
Requirement
Auditable
Events
Additional Audit
Record Contents
Sample Record
Failure of the
trusted channel
functions.
FTP_TRP.1
Initiation of the
trusted channel.
Termination of
the trusted
channel.
Failures of the
trusted path
functions.
Identification of
the claimed user
identity.
AUDIT: See logs provided by FCS_SSHS_EXT.1.
Table 8 Auditable Administrative Events
Requirement
Management Action to
Log
Sample Log
FAU_GEN.1: Audit data
generation
Changing logging settings.
Clearing logs.
Feb 17 2013 16:29:07: %PARSER-5-
CFGLOG_LOGGEDCMD: User:test_admin
logged command:logging enable
Feb 17 2013 16:34:02: %PARSER-5-
CFGLOG_LOGGEDCMD: User:test_admin
logged command:logging informational
Feb 17 2013 17:05:16: %PARSER-5-
CFGLOG_LOGGEDCMD: User:test_admin
logged command:clear logging
FAU_GEN.2: User identity
association
None
N/A
FAU_STG_EXT.1: Protected
Audit Event Storage
Configuration of syslog
export settings
Feb 17 2013 17:05:16: %PARSER-5-
CFGLOG_LOGGEDCMD: User:test_admin
logged command:logging host
FCS_CKM.1: Cryptographic
key generation (refined)
Manual key generation
Feb 17 2013 16:14:47: %PARSER-5-
CFGLOG_LOGGEDCMD: User:test_admin
logged command:crypto key *****

Table of Contents

Other manuals for Cisco ASR 1002

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco ASR 1002 and is the answer not in the manual?

Cisco ASR 1002 Specifications

General IconGeneral
Ethernet LANYes
Cabling technology10/100/1000Base-T(X)
Networking standardsIEEE 802.3
Ethernet LAN data rates10, 100, 1000 Mbit/s
Ethernet interface typeGigabit Ethernet
DHCP client-
Supported network protocolsBGP, GRE, OSPF, DVMRP, EIGRP, IS-IS, IGMPv3, PIM-SM, PIM-SSM
Ethernet LAN (RJ-45) ports4
Security algorithmsSSH
VPN tunnels quantity8000
SafetyUL60950-1 CSA, C22.2 No. 60950-1-03, EN 60950-1, IEC 60950-1, AS/NZS 60950.1
CertificationFCC 47CFR15 Class A AS/NZS CISPR 22 CISPR 22 Class A EN55022 Class A ICES-003 Class A VCCI Class A CNS-13438 Class A EN61000-3-2 EN61000-3-3
Internal memory4096 MB
AC input voltage85 - 264 V
Power source typeAC
AC input frequency50 - 60 Hz
Power consumption (typical)560 W
Operating altitude0 - 3048 m
Storage temperature (T-T)0 - 50 °C
Operating temperature (T-T)0 - 40 °C
Storage relative humidity (H-H)5 - 95 %
Operating relative humidity (H-H)5 - 90 %
Product colorGray
Rack capacity2U
Weight and Dimensions IconWeight and Dimensions
Depth461 mm
Width437.4 mm
Height89 mm
Weight- g