CHAPTER 3
Servicing a Blade Server
This chapter contains the following sections:
Replacing a Drive, page 11
Removing a Blade Server Cover, page 13
Internal Components, page 14
Diagnostics Button and LEDs, page 15
Installing the Front Mezzanine Storage Module, page 15
Mini-Storage Module, page 16
Removing and Installing CPUs and Heatsinks, page 28
Supported DIMMs, page 35
Installing a DIMM or DIMM Blank, page 36
DIMMs and Channels, page 37
Memory Performance, page 38
Memory Mirroring and RAS, page 39
Installing a Virtual Interface Card in the mLOM Slot, page 39
Installing a Rear Mezzanine Module in Addition to the mLOM VIC, page 40
NVIDIA P6 Graphics Processing Unit, page 42
Enabling the Trusted Platform Module, page 49
Replacing a Drive
The Cisco UCS B200 M5 blade server uses an optional front storage mezzanine module that has two drive
bays for hard disks or SSD drives, either 2.5-inch SAS, SATA, or NVMe. The storage mezzanine module
also supports a RAID controller. If you purchased the server without the front storage mezzanine module
configured as a part of the system, a pair of blanking panels may be in place. These panels should be removed
before installing disk drives, but should remain in place to ensure proper cooling and ventilation if the drive
bays are unused.
Cisco UCS B200 M5 Blade Server Installation and Service Note
11

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco UCS B200 M5 and is the answer not in the manual?

Cisco UCS B200 M5 Specifications

General IconGeneral
BrandCisco
ModelUCS B200 M5
CategoryServer
LanguageEnglish

Related product manuals