3-45
Cisco UCS C220 Server Installation and Service Guide
OL-25760-01
Chapter 3 Maintaining the Server
Installing or Replacing Server Components
Replacing the LSI RAID Battery Backup Unit or SuperCap Power Module
This server supports installation of one RAID battery backup unit (BBU) or one SuperCap Power
Module (SCPM). The unit mounts to a clip on the removable air baffle (see Figure 3-24).
Note If you are replacing a BBU on an older card, order the iBBU09 battery backup unit (UCS-RAID-BBU=).
The newer SuperCap power module is not compatible with older, non-CacheVault cards.
The SCPM provides approximately 3 years of backup for the disk write-back cache DRAM in the case
of sudden power loss by offloading the cache to the NAND flash.
Warning
There is danger of explosion if the battery is replaced incorrectly. Replace the battery only with the
same or equivalent type recommended by the manufacturer. Dispose of used batteries according to
the manufacturer’s instructions.
Statement 1015
To replace the RAID controller BBU or SCPM, follow these steps:
Step 1 Remove a backup unit (see Figure 3-24).
a. Power off the server as described in the “Shutting Down and Powering Off the Server” section on
page 3-7.
b. Slide the server out the front of the rack far enough so that you can remove the top cover. You might
have to detach cables from the rear panel to provide clearance.
Caution If you cannot safely view and access the component, remove the server from the rack.
c. Remove the top cover as described in the “Removing and Replacing the Server Top Cover” section
on page 3-8.
d. Disconnect the cable from the existing backup unit.
e. Slide the backup unit free of the clips on the air baffle mounting point (see Figure 3-24).
Step 2 Install a new backup unit:
a. Slide the new backup unit into the clips on the air baffle mounting point.
b. Connect the cable from the RAID controller to the new backup unit.
c. Replace the top cover.
d. Replace the server in the rack, replace cables, and then power on the server by pressing the Power
button.

Table of Contents

Other manuals for Cisco UCS C220 M3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco UCS C220 M3 and is the answer not in the manual?

Cisco UCS C220 M3 Specifications

General IconGeneral
Tcase70 °C
Bus typeQPI
SteppingM1
FSB ParityNo
Scalability2S
Processor cache10 MB
Processor cores4
System bus rate6.4 GT/s
Processor seriesIntel Xeon E5-2600
Processor socketLGA 2011 (Socket R)
Processor codenameSandy Bridge EP
Processor frequency2.4 GHz
Processor cache typeSmart Cache
Processor manufacturerIntel
Processor package size52.5 x 45.0 mm
Processor front side bus- MHz
Processor boost frequency2.50 GHz
Processor operating modes64-bit
ECC supported by processorYes
Graphics & IMC lithography32 nm
PCI Express configurationsx4, x8, x16
Supported instruction setsAVX
Thermal Design Power (TDP)80 W
Number of processors installed2
CPU multiplier (bus/core ratio)24
Physical Address Extension (PAE)46 bit
Maximum number of PCI Express lanes40
Memory types supported by processorDDR3-SDRAM
Memory channels supported by processorQuad
Memory clock speeds supported by processor800, 1066 MHz
Memory bandwidth supported by processor (max)34.1 GB/s
Maximum internal memory supported by processor750 GB
HDD size2.5 \
HDD interface-
Total storage capacity500 GB
Compatible memory cardsSD
Maximum storage capacity- TB
Memory slots16
Internal memory32 GB
Memory clock speed1866 MHz
Maximum internal memory- GB
USB 2.0 ports quantityUSB 2.0 ports have a data transmission speed of 480 Mbps, and are backwards compatible with USB 1.1 ports. You can connect all kinds of peripheral devices to them.
Ethernet LAN (RJ-45) ports3
Chassis typeRack (1U)
Power supply450 W
SafetyUL 60950-1 No. 21CFR1040, CAN/CSA-C22.2 No. 60950-1, IEC 60950-1, EN 60950-1, IEC 60950-1, AS/NZS 60950-1, GB4943 2001
Certification47CFR Part 15 (CFR 47), AS/NZS CISPR22, CISPR2 2, EN55022, ICES003, VCCI, EN61000-3-2, EN61000-3-3, KN22, CNS13438, EN55024, CISPR24, EN300386, KN24
Operating altitude0 - 3000 m
Non-operating altitude0 - 12000 m
Storage temperature (T-T)-40 - 70 °C
Operating temperature (T-T)0 - 40 °C
Storage relative humidity (H-H)5 - 93 %
Operating relative humidity (H-H)10 - 90 %
PCI Express slots version3.0
Processor ARK ID64588
Intel Secure Key Technology version1.00
Intel Identity Protection Technology version0.00
Harmonized System (HS) code84714100
Weight and Dimensions IconWeight and Dimensions
Depth724 mm
Width430 mm
Height43.2 mm