EasyManuals Logo
Home>DAB>Water Pump>e.sybox mini3

DAB e.sybox mini3 User Manual

DAB e.sybox mini3
75 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #23 background imageLoading...
Page #23 background image
ENGLISH
EN
58
5.1.13 - Output ow meter
The page shows two ow meters. The rst shows the total output ow
delivered by the machine. The second shows a partial count and can be
reset by the user. The partial count can be reset from this page, by holding
down the “ - “ button for 2 sec.
5.1.14 - VE: Version display
Hardware and software version with which the appliance is equipped.
Hardware and software 2.7.0 and later, the following also applies:
on this page after the prex S: the last 5 gures of the single serial number
attributed for connectivity are showed. The whole serial number can be
viewed by pressing the “+” key.”
5.1.15- FF: Fault log display
Chronological display of the faults that have occurred during system op-
eration.
Under the symbol FF appear two numbers x/y indicating respectively the
ault displayed and the total number of faults present; to the right of these
numbers is an indication of the type of fault displayed.
The + and keys scroll through the list of faults: pressing the – key goes
back through the log and stops at the oldest fault present, pressing the +
key goes forward in the log and stops at the most recent fault.
The faults are displayed in chronological order starting from the one that
appeared farthest back in time x=1 to the most recent x=y. The maximum
number of faults that can be shown is 64; when that number is reached,
the log starts to overwrite the oldest ones.
This item on the menu displays the list of faults, but does not allow reset.
Reset can be carried out only with the dedicated control from item RF on
the TECHNICAL ASSISTANCE MENU.
The fault log cannot be deleted with a manual reset, by switching off the
appliance, or by resetting the factory values, unless the procedure de-
scribed above has been followed.
5.2 - Monitor Menu
From the main menu, by holding down simultaneously for 2 sec the keys
“SET” and “-“ (minus), or using the selection menu and pressing + or -, you
can access the MONITOR MENU.
In this menu, by pressing the MODE key, the following values are dis-
played in sequence.
5.2.1 - CT: Display contrast
Adjusts the display contrast.
5.2.2 - BK: Display brightness
Adjusts the backlighting of the display on a scale from 0 to 100.
5.2.3 - TK: Backlight switch-on time
Sets the time that the backlight is lit since the last time a key was pressed.
Values allowed: ‘0’ always off; from 20 sec to 10 min or ‘always on’.
When the backlight is off, the rst time any key is pressed has the sole ef-
fect of restoring the backlighting.
5.2.4 - LA: Language
Display in one of the following languages:
Italian
English
French
German
Spanish
Dutch
Swedish
Turkish
Slovak
Romanian
Russian
Thai
5.2.5 - TE: Dissipator temperature display
5.3 - Setpoint Menu
From the main menu, hold down simultaneously the “MODE” and “SET”
keys until “SP” appears on the display (or use the selection menu pressing
+ or -). The + and – keys allow you respectively to increase and decrease
the plant boosting pressure.
Press SET to leave this menu and return to the main menu.
The range of adjustment is 1-5.5 bar (14-80 psi).

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the DAB e.sybox mini3 and is the answer not in the manual?

DAB e.sybox mini3 Specifications

General IconGeneral
BrandDAB
Modele.sybox mini3
CategoryWater Pump
LanguageEnglish

Related product manuals