10 | Configuration
Installer reference guide
142
EPRA08~12EAV3+W1 + ETVH12SU18+23EA6V
Daikin Altherma 3 H MT F
4P644482-1 – 2021.03
Item Description
k Additional zone
k1 Installed room thermostat type:
Unit operation is decided by the external room thermostat
(wired or wireless).
— No room thermostat installed or set. Unit operation is
decided based on the leaving water temperature regardless
of the actual room temperature and/or heating demand of
the room.
k2 Installed heat emitter type:
Underfloor heating
Fancoil unit
Radiator
k3
Leaving water temperature setpoint
(a)
l Malfunction
A malfunction occurred.
See "14.4.1To display the help text in case of a
malfunction"[4254] for more information.
(a)
If the corresponding operation (for example: space heating) is not active, the circle is
greyed out.
10.3.3 Main menu screen
Starting from the home screen, press ( ) or turn ( ) the left dial to open
the main menu screen. From the main menu, you can access the different setpoint
screens and submenus.
2
Main zone
Additional zone
Room
Malfunctioning
Space heating/cooling
a Selected submenu
Possible actions on this screen
Go through the list.
Enter the submenu.
Enable/disable breadcrumbs.
Submenu Description
[0]
or Malfunctioning
Restriction: Only displayed if a malfunction
occurs.
See "14.4.1To display the help text in case of
a malfunction"[4254] for more information.