EDUS041111_a Capacity Tables
Room Air Conditioners K-Series 19
7. Capacity Tables
7.1 Cooling Only
FTXN09KEVJU + RKN09KEVJU (60 Hz, 208 / 230 V)
3D072390
AFR 9.2
BF 0.20
Temp: Celsius
TC, SHC, PI: kW
INDOOR OUTDOOR TEMPERATURE (°CDB)
EWB EDB 20.0 25.0 30.0 32.0 35.0 40.0
°C °C TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI
14.020.02.421.940.552.421.940.622.421.940.682.411.930.712.341.890.742.211.840.80
16.022.02.832.040.582.701.980.632.581.920.692.531.900.712.461.870.752.331.820.80
18.025.02.952.140.582.832.090.642.702.040.692.652.020.722.581.990.752.461.940.80
19.426.73.012.270.582.892.220.642.762.170.692.712.150.72
2.64 2.12 0.75 2.52 2.07 0.81
22.030.03.192.190.593.072.150.642.952.100.702.902.090.722.822.060.752.702.020.81
24.032.03.312.140.593.192.100.653.072.060.703.022.040.732.942.020.762.821.980.81
Temp: Fahrenheit
TC, SHC: kBtu/h
PI: kW
INDOOR OUTDOOR TEMPERATURE (°FDB)
EWB EDB 68.0 77.0 86.0 90.0 95.0 104.0
°F °F TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI
57.268.08.275.670.538.275.670.608.275.670.688.215.620.717.965.420.747.545.090.75
60.871.69.646.430.589.226.070.638.805.730.698.635.590.718.385.400.757.965.080.75
64.4 77.0 10.05 6.48 0.58 9.63 6.14 0.64 9.21 5.81 0.69 9.04 5.68 0.72 8.79 5.49 0.75 8.37 5.18 0.76
67.0 80.0 10.26 6.56 0.58 9.84 6.23 0.64 9.42 5.91 0.69 9.25 5.78 0.72
9.00 5.60 0.75 8.58 5.30 0.76
71.6 86.0 10.88 6.30 0.59 10.46 5.99 0.64 10.04 5.70 0.70 9.87 5.58 0.72 9.62 5.41 0.75 9.20 5.14 0.76
75.2 89.6 11.29 6.08 0.59 10.87 5.79 0.65 10.46 5.51 0.70 10.29 5.41 0.73 10.04 5.25 0.76 9.62 4.99 0.76
Symbols: Note:
AFR : Airflow rate (m
3
/min.) 1. Ratings shown are net capacities which include a deduction for indoor fan
motor heat.
2. shows nominal (rated) capacities and power input.
3. TC, PI and SHC must be calculated by interpolation using the figures in the
above tables. (Figures out of the tables should not be used for calculation.)
4. About SHC which are not mentioned on the table, please calculate them with
around values in direct proportion.
5. Capacities are based on the following conditions.
Corresponding refrigerant piping length : 25 ft
Level difference : 0 ft
6. Airflow rate (AFR) and Bypass factor (BF) are tabulated above table.
BF : Bypass factor
EWB : Entering wet bulb temp. (°C) / (°F)
EDB : Entering dry bulb temp. (°C) / (°F)
TC : Total capacity (kW) / (kBtu/h)
SHC : Sensible heating capacity (kW) / (kBtu/h)
PI : Power input (kW)