2 Manual RS8FS402 © Danfoss 2016-03 AK-CC 550A
Introduction
Application
Complete refrigeration appliance control with great exibility to
adapt to all types of refrigeration appliances and cold storage
rooms.
Advantages
Energy optimization of the whole refrigeration appliance
One controller for several dierent refrigeration appliances
Integrated display at the front of the controller
Quick set-up with predened settings
Built-in data communication
Built-in clock function with power reserve
Principle
The temperature in the appliance is registered by one or two
temperature sensors which are located in the air ow before the
evaporator (S3) or after the evaporator (S4) respectively. A setting
for thermostat, alarm thermostat and display reading determines
the inuence the two sensor values should have for each indi-
vidual function.
In addition product sensor S6, which can be optionally placed in
the appliance, can be used to register the temperature near the
required product in a certain place within the appliance.
The temperature of the evaporator is registered with the S5 sensor
which can be used as a defrosting sensor.
In addition to the outlet to the electronic injection valve of the
type AKV, the controller has 5 relay outputs which are dened by
the use selected – the individual usage options are described in
detail on page 12.
Functions
Day/night thermostat with ON/OFF or modulating principle
Product sensor S6 with separate alarm limits
Switch between thermostat settings via digital input
Adaptive control of superheat
Adaptive defrosting based on evaporator performance
Start of defrost via schedule, digital input or network
Natural, electric or hot gas defrost
Stop of defrost on time and/or temperature
Coordination of defrosting among several controls
Pulsing of fans when thermostat is satised
Appliance cleaning function for documentation of HACCP proce-
dure
Rail heat control via day/night load or dew point
Door function
Control of two compressors
Control of night blinds
Light control
Heat thermostat
Factory calibration that will guarantee a better measuring accu-
racy than stated in the standard EN 441-13 without subsequent
calibration (Pt 1000 ohm sensor)
Integrated MODBUS communication with the option of mount-
ing a LonWorks communication card
Appliance examples
Contents
Introduction ....................................................................................................... 2
Operation ............................................................................................................ 4
Applications .....................................................................................................12
Survey of functions ........................................................................................15
Operation ..........................................................................................................26
Menu survey .....................................................................................................28
Connections .....................................................................................................32
Data .....................................................................................................................34
Ordering ............................................................................................................35

Other manuals for Danfoss AK-CC 550A

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss AK-CC 550A and is the answer not in the manual?

Danfoss AK-CC 550A Specifications

General IconGeneral
BrandDanfoss
ModelAK-CC 550A
CategoryController
LanguageEnglish

Related product manuals